Safety Instructions (continued)

Note

•When conformity to UL is required, the SI unit should be used

with a UL1310 Class 2 power supply.

Follow the instructions given below when handling your product.
Or, it will have a risk of being damaged and operating failure.

•Operate product with the specified voltage.
•Reserve a space for maintenance.
•Do not remove labels.
•Do not drop, hit or apply excessive shock to the product.
•Follow the specified tightening torque.
•Never mount a product in a location that will be used as a

foothold.

•Do not bend or apply tensile force to cables, or apply force by

placing heavy load on them.

•Connect wires and cables correctly.
•Do not connect wires while the power is on.
•Do not lay wires or cables with power line or high-voltage line in

the same wiring route.

•Verify the insulation of wiring.
•Separate power line for solenoid valves from power line for

Input and control unit.

•Take appropriate measures against noise, such as using a

noise filter, when the product is incorporated into equipment.

•Select the proper type of protection according to the

environment of operation.

•Take sufficient shielding measures when installing at the

following place.

(1) A place where noise due to static electricity is generated
(2) A place where electric field strength is high
(3) A place where there is radioactive irradiation
(4) A place near power line

•Do not use the product near by a place where electric surges

are generated.

•When a surge-generating load such as a relay or solenoid is

driven directly, use an product with a built-in surge absorbing
element.

•The product is CE marked, but not immune to lightning strikes.

Take measures against lightning strikes in the system.

•Prevent foreign matter such as remnant of wires from entering

the product to avoid failure and malfunction.

•Mount the product in a place that is not exposed to vibration or

impact.

•Do not use the product in an environment that is exposed to

temperature cycle.

•Do not expose the product to direct sunlight.
•Keep the specified ambient temperature range.
•Do not expose the product to heat radiation from a heat source

located nearby.

•Set the switches by using a sharp-pointed screwdriver etc.
•Turn off the power supply, stop the supplied air, exhaust the

residual pressure and verify the release of air before performing
maintenance.

•Perform maintenance and check regularly.
•Perform a proper functional check.
•Do not use solvents such as benzene, thinner etc. to clean the

product.

Summary of Contents for EX510-GPR1 Series

Page 1: ...tions are subject to change without prior notice and any obligation on the part of the manufacturer 2009 2017 SMC Corporation All Rights Reserved EX OMH0024 C Akihabara UDX 15F 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Phone 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com ...

Page 2: ...tuses that use fieldbus system and have full knowledge of assembly operation and maintenance of such equipment Please read this operation manual carefully and understand it before assembling operating or providing maintenance service to the actuator Thank you for purchasing an SMC fieldbus system EX510 series Please read this manual carefully before operating the product and make sure you understa...

Page 3: ...or damage to the product can result Verify the specifications before use Do not disassemble modify including change of printed circuit board or repair An injury or failure can result IMPORTANT MESSAGES Do not operate in an atmosphere containing flammable or explosive gases Fire or an explosion can result This product is not designed to be explosion proof If using the product in an interlocking cir...

Page 4: ...easures when installing at the following place 1 A place where noise due to static electricity is generated 2 A place where electric field strength is high 3 A place where there is radioactive irradiation 4 A place near power line Do not use the product near by a place where electric surges are generated When a surge generating load such as a relay or solenoid is driven directly use an product wit...

Page 5: ...7 6 Communication connector for PROFIBUS DP 1 piece Power supply connector 2 pieces Accessory ...

Page 6: ...16 PWR V PWR BUS ...

Page 7: ...s 500 kbps 1500 kbps 3000 kbps 6000 kbps 12000 kbps 1000 m 400 m 200 m Synchronous function Available Address setting range 0 to 125 Max wiring length differs depending on the specification of a cable The specification of wiring length is based on type A cable Number of branches for input output 4 branches for input 4 branches for output Communication type Communication protocol Dedicated for SMC ...

Page 8: ...anch cables and be connected with branch connectors SI unit and Input unit have 2 branch connectors for each Pressure welding for branch connector The method of pressure welding for branch connector is explained 1 Components 2 Working procedure Set a branch cable to the cover 1 Set the brown wire of the branch cable so that it comes to the pin 1 2 Meet the cable end to the insulating cap at the co...

Page 9: ... Wiring continued 3 Refer to Drawing 4 about how to connect to the unit VP RxD TxD N DGND RxD TxD P SHIELD Green Red Shield Green Red Shield VP 390 Ω RxD TxD P Data Line Data Line RxD TxD N 220 Ω 390 Ω DGND ...

Page 10: ... connectors Power supply structure consists of 2 systems but it can be used with both single power supply and separate power supply Individual power supply for other units is not necessary Make sure of connection with the designated pin Tighten the connector securely to 0 5 to 0 6 Nm tightening torque ...

Page 11: ...OLD Output is held when a communication error occurs No 9 OFF ON Mode HW Function Set Address with SW1 to 7 SW Address are set by network The setting when shipped from plant is 126 SW1 to 7 are ignored No 10 OFF ON HOLD CLR setting is made available per one point by parameter setting Refer to Operation Manual for detail 0 OFF OFF OFF OFF OFF OFF OFF Setting of the address 126 and 127 are invalid U...

Page 12: ...ED for power supply PWR and the LED for communication COM at SI unit are ON Ensure output branch current does not exceed the specification range Program it after checking the wiring specification of manifold block assembly Check the power for input and controlling GW 24 VDC is supplied Check the input unit indication LED is ON Ensure input branch current does not exceed the specification range Che...

Page 13: ... is correct Check the connecting condition of the terminating resistor Check the number of input output is set correctly 2 DIA LED is lights up Check the power for output 24 VDC is powered at a specified voltage Check the power supply voltage for output is above 20 V Check the input unit is connected after the input port No Item Remedy Disposal Refer to Operation Manual for detail of troubleshooti...

Reviews: