-8-
No.EX
※※
-OMU1021-A
System Outline
System configuration
The EX600-SEN5-X16(SI unit) can communicated to EtherNet/IP.
SI unit has the following features.
・
Number of valve outputs : Max.32 outputs
・
Number of Digital input units : Max.3 units (EX600-DXPD-X16)
・
Number of Digital output units : Max.3 units (EX600-DYPB-X16)
Name
Function
SI unit
(EX600-SEN5-X16)
Performs fieldbus communication and solenoid valve manifold ON/OFF output.
Digital input unit
(EX600-DXPD-X16)
For connecting sensors with switch output capability.
Digital Output unit
(EX600-DYPB-X16)
For connecting output device such as solenoid valves, lamps, buzzers, etc.
End plate
(EX600-ED3-X16)
Connected at EX600 Mani
fold’s D side, incorporating the power supply connection.
Solenoid valve manifold
An assembly of solenoid valves. One connector is used as the electric connection to all
connected valves.
End
plate
Digital input
unit
SI unit
Solenoid valve manifold
Digital Output
unit