5/8 

FGX-OM-L010 

2. Specifications 

 

Table 2. Specifications 

 

Parameter 

Cantent 

Note 

Operating fluid 

Fluid only 

Gas is not allowed 

Max. operating 

pressure

 

0.7MPa 

 

Max. operating temp. 

 

80℃ 

 

Capacity

 

27L,43L,52L 

Weight

 

19.5kg,23kg,30kg 

Depends on element length 

Applicable regulation 

and standard

 

Not applied 

 

Vessel 

Accessory

 

Pressure 

gauge

 

To measure inlet and outlet

pressure 

Mountable(Option available) 

Material 

Filtration

 

Element 

Element differential 

element proof

 

Depends on element 

See element specification for details

Others 

Element replacement 

differential pressure 

0.1MPa 

(Differential pressure) 

 

 

3. Installation / Piping

 

 

1

Installation

   

      ・

Fix the feet to the ground firmly using foundation bolt(M12).   

Install and arrange piping at the place with enough space for maintenance.

  

 

2

Piping

 

      ・

Check connect port size to use valves and fitting suitable for operating conditions.   

   

Arrange the piping so that pressure in the product can be released.   

Confirm cautions on page 2 and 3 for use.   

 

 

4. Operation

 

 

1

Operation 

      ・

Mount V band to specified position. Confirm connecting parts and seal do not leak before start 

operation.  

      ・

When starting operation, open upper relief port(loosen hex. plug) to discharge air.   

2

Replacing the element 

      ・

Replace the element when pressure drop become lower than specification value.   

     

For the replacement of the element, see Replacement of the element on page 6.   

Confirm cautions on page 2 and 3 for use. 

 

 

 

Summary of Contents for FGG 20 A Series

Page 1: ...understand its content before installing and using the product Give special attention to safety instructions Keep this operation manual available whenever necessary OPERATION MANUAL SMC Filter FGG series FGG 20 A SMC Corporation INDEX Safety Instruction P2 3 Construction P4 Specification P5 Installation Piping P5 Operation P5 Replacement of the element P6 7 Packing material Select option Select el...

Page 2: ... Do not use in corrosive environment Do not use where exposed to vibration or impact Caution on operation Warning Do not loosen V band while pressure is applied Install V band correctly to specified position See page 7 Replace deteriorated or swollen O ring Replace O ring in one year after starting use or fluid leakage occurs See page 4 Table 1 O ring for replacement When supplying pressure for st...

Page 3: ...ng Caution Ensure the direction of IN OUT for piping Arrange piping so that air discharging work is available Check each port size for selecting valves and fitting suitable for operating conditions Flush piping line with air before operation to check any problem including fluid leakage Fix the feet to the ground firmly using foundation bolt M12 The piping of INLET and OUTLET shall be fixed firmly ...

Page 4: ... space between element AL 25S NBR O ring AL 22S FKM O ring used to seal the sealing part of the cover and the case V band CY 27S SUS304 SWCH Engage the cover and the case and settle Them Cover SUS304 The lid of the product Case SUS304 Main body of the case Foot SS400 Support the body Fix to the ground Description on label BH 73S Tetlon Caution label BH 77S Tetlon Caution When becomes dirty replace...

Page 5: ...nstallation Piping 1 Installation Fix the feet to the ground firmly using foundation bolt M12 Install and arrange piping at the place with enough space for maintenance 2 Piping Check connect port size to use valves and fitting suitable for operating conditions Arrange the piping so that pressure in the product can be released Confirm cautions on page 2 and 3 for use 4 Operation 1 Operation Mount V...

Page 6: ...6 8 FGX OM L010 ...

Page 7: ...sition from where clamping position check pin can be inserted and insert the clamping position check pin See Fig c When tightening nut can not be tightened to specified position position where clamping position check pin can be inserted replace V band and O ring to new ones See table 1 Caution Clean V band and the contact surface between the cover and the case before mounting Dirty contact surface...

Page 8: ...bara UDX 15F 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Phone 81 3 5207 8249 Fax 81 3 5298 5362 Specifications are subject to change without prior notice and any obligation the part of the manufacturer 2008 SMC Corporation All Rights Reserved ...

Reviews: