Caution

SMC products are not intended for use as instruments for legal 

metrology.

Measurement instruments that SMC manufactures or sells have not been 

qualified by type approval tests relevant to the metrology (measurement) laws 

of each country. Therefore, SMC products cannot be used for business or 

certification ordained by the metrology (measurement) laws of each country.

Compliance Requirements

1) ISO 4414: Pneumatic fluid power – General rules relating to systems.

  ISO 4413: Hydraulic fluid power – General rules relating to systems.

  IEC 60204-1: Safety of machinery – Electrical equipment of machines.

 

(Part 1: General requirements)

  ISO 10218-1: Manipulating industrial robots – Safety.

 etc.

Caution

 indicates a hazard with a low level of risk which, 

if not avoided, could result in minor or moderate injury.

Caution:

Warning

 indicates a hazard with a medium level of risk which, 

if not avoided, could result in death or serious injury.

Warning:

Danger :

Danger

 indicates a hazard with a high level of risk which, 

if not avoided, will result in death or serious injury.

Warning

Caution

1. The compatibility of the product is the responsibility of the 

person who designs the equipment or decides its 

specifications.

Since the product specified here is used under various operating conditions, 

its compatibility with specific equipment must be decided by the person who 

designs the equipment or decides its specifications based on necessary 

analysis and test results. The expected performance and safety assurance 

of the equipment will be the responsibility of the person who has determined 

its compatibility with the product. This person should also continuously 

review all specifications of the product referring to its latest catalog 

information, with a view to giving due consideration to any possibility of 

equipment failure when configuring the equipment.

2. Only personnel with appropriate training should operate 

machinery and equipment.

The product specified here may become unsafe if handled incorrectly. The 

assembly, operation and maintenance of machines or equipment including 

our products must be performed by an operator who is appropriately trained 

and experienced.

3. Do not service or attempt to remove product and machinery/

equipment until safety is confirmed.

1. The inspection and maintenance of machinery/equipment should only be 

performed after measures to prevent falling or runaway of the driven 

objects have been confirmed. 

2. When the product is to be removed, confirm that the safety measures as 

mentioned above are implemented and the power from any appropriate 

source is cut, and read and understand the specific product precautions 

of all relevant products carefully.

3. Before machinery/equipment is restarted, take measures to prevent 

unexpected operation and malfunction.  

4.  Contact SMC beforehand and take special consideration of 

safety measures if the product is to be used in any of the 

following conditions. 

 

1. Conditions and environments outside of the given specifications, or use 

outdoors or in a place exposed to direct sunlight.

2. Installation on equipment in conjunction with atomic energy, railways, air 

navigation, space, shipping, vehicles, military, medical treatment, 

combustion and recreation, or equipment in contact with food and 

beverages, emergency stop circuits, clutch and brake circuits in press 

applications, safety equipment or other applications unsuitable for the 

standard specifications described in the product catalog. 

3. An application which could have negative effects on people, property, or 

animals requiring special safety analysis. 

4. Use in an interlock circuit, which requires the provision of double interlock 

for possible failure by using a mechanical protective function, and 

periodical checks to confirm proper operation.

1. The product is provided for use in manufacturing industries.

The product herein described is basically provided for peaceful use in 

manufacturing industries. 

If considering using the product in other industries, consult SMC beforehand 

and exchange specifications or a contract if necessary. 

If anything is unclear, contact your nearest sales branch.

Limited warranty and Disclaimer/

Compliance Requirements

The product used is subject to the following “Limited warranty and Disclaimer” and 

“Compliance Requirements”.

Read and accept them before using the product.

Limited warranty and Disclaimer

1. The warranty period of the product is 1 year in service or 1.5 years after 

the product is delivered, whichever is first.

2)

Also, the product may have specified durability, running distance or 

replacement parts. Please consult your nearest sales branch.

2. For any failure or damage reported within the warranty period which is clearly our 

responsibility, a replacement product or necessary parts will be provided. 

This limited warranty applies only to our product independently, and not to any 

other damage incurred due to the failure of the product.

3. Prior to using SMC products, please read and understand the warranty terms 

and disclaimers noted in the specified catalog for the particular products.

2) Vacuum pads are excluded from this 1 year warranty.

A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. 

Also, even within the warranty period, the wear of a product due to the use of the vacuum pad 

or failure due to the deterioration of rubber material are not covered by the limited warranty.

1. The use of SMC products with production equipment for the manufacture of 

weapons of mass destruction (WMD) or any other weapon is strictly prohibited.

2. The exports of SMC products or technology from one country to another are 

governed by the relevant security laws and regulations of the countries involved 

in the transaction. Prior to the shipment of a SMC product to another country, 

assure that all local rules governing that export are known and followed.

Safety Instructions

Be sure to read “Handling Precautions for SMC Products” (M-E03-3) before using.

These safety instructions are intended to prevent hazardous situations and/or 

equipment damage. These instructions indicate the level of potential hazard with 

the labels of “Caution,” “Warning” or “Danger. They are all important notes for 

safety and must be followed in addition to International Standards (ISO/IEC)

1)

and other safety regulations.

Safety Instructions

© 2014 SMC Corporation of America, All Rights Reserved.
All reasonable efforts to ensure the accuracy of the information detailed in this catalog were made at the time of publishing.

However, SMC can in no way warrant the information herein contained as specifications are subject to change without notice.

SZ-RRD-2.5M

Summary of Contents for HECR Series

Page 1: ...18to 0 054 F 0 01 to 0 03 C Temperature stability 50 to 140 F 10 to 60 C Set temperature range 200 w Cooling capacity 440 w 100 V input 4 6 A Power consumption Energy saving Good space utilization Hei...

Page 2: ...uid volume can be checked q Turn the power ON w Press the SEL key and adjust the temperature setting with the keys e Press the RET key to complete Canpreciselycontrolthetemperatureofaheatsourceorproce...

Page 3: ...poses a Peltier device thermo module between the heat exchangers for the circulating fluid and facility water and controls the DC power supply to achieve the target outlet temperature of circulating f...

Page 4: ...aling Electronic microscope Ultra sonic wave inspection machine Cooling of laser irradiated part Temperature control of X ray tube and X ray light sensing part Cooling of laser irradiated part Cooling...

Page 5: ...pacity Page 8 Heating Capacity Page 8 Pump Capacity Thermo con Outlet Page 8 Dimensions Page 9 Operation Display Panel Page 10 Alarm Page 10 Maintenance Page 10 Options With Feet and No Rack Mounting...

Page 6: ...ssary select the Peltier type Thermo con HEC series refer to the following or the refrigerated Thermo chiller HRS HRZ series 3 How much cooling capacity required Guide to Model Selection Cooling capac...

Page 7: ...x 103 x 4 2 x 103 60 x 1000 167 W 200 W Cooling capacity Considering a safety factor of 20 167 W x 1 2 Water Density 1 x 103 kg m3 Specific heat C 4 2 x 103 J kg K Cooled substance total volume V Cool...

Page 8: ...ty Note 2 0 018 to 0 054 0 01 to 0 03 C Pump capacity Refer to the performance charts Page 8 Tank capacity Approx 0 34 gal 1 3 L Port size Rc1 4 Wetted parts material Stainless steel EPDM Ceramics PPE...

Page 9: ...300 200 100 0 0 Circulating fluid Water Ambient temperature 59 F 15 C Ambient temperature 95 F 35 F Heating capacity W 1000 900 800 700 600 500 400 300 200 100 0 0 Circulating fluid Ethylene glycol 2...

Page 10: ...ng removing the product to from the rack Circulating fluid inlet Circulating fluid drain port Rc1 4 Circulating fluid outlet Rc1 4 Dimensions HECR002 A5 1 Power supply connector IEC60320 C14 or equiva...

Page 11: ...disconnected or short circuited ERR18 External temp sensor disconnection alarm Continue The external temperature sensor has been disconnected or short circuited Only detected when in learning control...

Page 12: ...kets and handles on the front side are removed as they are not necessary when the product is not mounted in a rack This option has rubber feet for installing the product on the floor E F F HECR002 A5...

Page 13: ...e connector on the Thermo con side in position For single phase 200 VAC type Also applicable for the 100 VAC type but the connector for the user s equipment needs to be prepared by the user Part no Ap...

Page 14: ...he product weight is held with the bottom surface of the product Use the handles on the front side of the product when installing removing the product to from the rack 1 The inlet for radiation air mu...

Page 15: ...tank is made of resin PE Therefore the tank may be crushed if the pressure is negative Special attention must be paid if the flow rate of the circulating fluid is high To avoid getting negative press...

Page 16: ...on or equipment in contact with food and beverages emergency stop circuits clutch and brake circuits in press applications safety equipment or other applications unsuitable for the standard specificat...

Reviews: