2 Transportation / Installation
2-3 Cautions
for Reinstallation
2
-
5
IDFA Series
2-3
Cautions for Reinstallation
Caution
Only properly trained, qualified personnel are allowed to perform reinstallation.
If the product is moved and reinstalled in another place after some trial operations, the following instructions
must be followed as well as procedures in Chapter 2.
Removing the power cable
Disconnect the power source before removing the power cable.
Warning
・
Only properly trained, qualified personnel are allowed to perform wiring.
・
Disconnect the power source before wiring. Do not work under energized
condition
Disconnecting air pipes
Warning
・
Only properly trained, qualified personnel are allowed to perform piping works.
・
Separate the compressor from the product before disconnecting the air pipe.
・
Do not disconnect any piping when there is residual air pressure inside of the pipe.
Remove the seal tape completely after removing the piping. Loose seal tape can clog up the system.
Releasing residual pressure
・
Bypass valve should open even after the dryer has been removed.
・
Close the compressed air inlet and outlet valve.
・
Unscrew the front panel screws (in 2 places) and remove the front panel.
・
Open the auto drain residual pressure release valve to release air pressure inside the product. Refer to
the
Figure of right.