Air Dryer
10 Specification for Option L
10-3 Maintenance
10 - 2
IDX-OM-I076
IDFA Series
Note) Use for air compressor with flow more than 3m
3
/ h (ANR).
10-3 Maintenance
1. Check drain condition periodically (more than once a day).
Then push flushing button to open exhaust valve.
2. Pilot air is exhaust from the port indicated in the figure. Do not cover this exhaust port.
Clean exhaust port so that port is not blocked by dust, etc.
3. Close the ball valve before removing the heavy duty auto drain and open the bleed valve or push the
flushing button and confirm air pressure is released.
Model
IDFA22E to 75E-23-L
Order number (service parts)
ADH-E400
Auto drain type
Floating type
Auto drain valve type
N.O(normally opened: Open in the case of pressure loss)
Max. operating pressure
1.6MPa
Working pressure range
0.05 to 1.6MPa
Working fluid
Compressed air
Max. drain discharge
0.024m
3
/ h (Pressure 0.7MPa,the case of water)