IDX-OM-V024
Chapter
3
Transportation and installation
IDFB60/70/80/90 Series
3.2
Installation
3-5
3.2.5
Electrical wiring
Power supply cable specification
- Prepare the power supply cables below.
- Approx. 0.2m of cable is necessary for wiring in the product.
IDFB60-23
IDFB70-23
IDFB80-23
IDFB90-23
16AWG (1.25mm
2
),
12AWG (3.5mm
2
)
10AWG (5.5mm
2
)
Cable O.D. Approx. 9 to 11mm.
Cable O.D. Approx. 18 to 23mm.
Power supply
- Connect the power cable and grounding cable to the terminal block. Use round crimp terminal for
connection terminal.
IDFB60-23
IDFB70-23
IDFB80-23
IDFB90-23
Terminal screws
M3.5
M4.0
Applicable crimp terminal
1.25-3.5
3.5-4
5.5-4
(Terminal width 8.5mm and below)
(Terminal width 9.5mm and below)
- Only qualified personnel should do electrical wiring work.
- Cut off the power supply for safety before the wiring. Wiring with the product energized is
strictly prohibited.
- Use a power supply suitable for the specifications of the product.
- Supply power from a stable place, which is free from the effects of any surge.
- Do not plug too many leads into a single socket. It can cause a fire.
- Supply power from a system with an emergency stop equipped.
- To avoid electric shock and burnout of the compressor motor, select the earth leakage
breaker with the correct sensitivity of leakage current and load capacity and mount to the
supply power side referring to the Chapter 7.1 Specifications.
- Install the breaker correctly, so that all power can be shut off and easy access to the operation
panel is realized.
- Install a breaker compliant with applicable local safety regulations and standards.
- The equipment should be grounded for safety.
- Add an allowance to the length of the grounding cable so that external force is not applied to it.
- Connect the grounding cable first before connecting other cables, and remove it last when
removing cables.
- Do not connect the earth to a water pipe, a gas pipe, or a lightening rod.
- Do not modify the internal electrical wiring of the product.
- For use in Europe, install a breaker compliant with applicable IEC standards to the power
supply of the product.
WARNING