3.Start and stop
3 - 2
Caution
- Frequently turning on and off the switch can cause failure.
- Since the auto drain of the product is designed in such a way that the valve closes at
0.05MPa or higher (N.C. type), air will blow out from the drain port when the pressure
increases. Therefore, if the air compressor has a small air delivery, the pressure may not
be sufficient.
3.3 Stop
1) Turn off the switch with lamp.
2) The lamp will go off and operation will stop.
3.4 Precautions for restarting operation
- Allow at least 3 minutes before restarting the product. If the product is restarted within 3 minutes after
being stopped, the protection circuit will be activated, operating light will turn off and the dryer will not be
activated.
If operation cannot be restarted, refer to “Chapter 5 Troubleshooting” to solve it.
3.5 Check items after starting
Check the following items when starting the product. Immediately stop the operation in the event of failure.
Turn off the switch with lamp and shut off the breaker of the main power supply.
- There is no compressed air leakage.
- The pressure, temperature, flow rate and ambient temperature of the compressed air are within the
specified range.
- Condensate is coming out from the drain tube.
- The evaporation thermometer is in the green area.
- There is no abnormal sound, vibration or odor from the product.
3.6 Precautions for long-term non-operation
If the product will not be operated for 24 hours, for example at the weekend, turn off the Switch with lamp
or power supply, for energy saving and safety. It is also recommended to release the pressure inside the
compressed air piping and this air dryer.