12. Specification for Option V
12- 1
12.1
Safety instructions
When handling the product, take care to the following precautions.
Warning
- Do not remove the auto drain with the air pressure remaining internally. If the compressed
air is left in the product, when some part is loosened, it may cause sudden lurching or
other unexpected accidents.
- When removing the panel, wear protective gloves to prevent injuries.
- There is a risk of touching drained waste liquid during replacement.
When draining, follow the user’s own procedure to keep operators safe. (E.g. Wear
protective goggles, apron and gloves to prevent contact with the drained condensate.)
- When oils can enter the drained condensate, waste water treatment is necessary. Follow the
bylaws or rules of the local municipality for disposal.
Warning
Only qualified persons are allowed to wire the product.
- Use a power supply suitable for the specifications of the product.
- Be sure to connect the ground connection.
- Grounding should never be connected to a water line, gas line or lightning rod.
- Multiple wiring is dangerous because it may lead to heat generation and cause a fire.
- Do not modify the electrical wiring of the power supply.
12.2
Specifications
The float type auto drain used in the standard air dryer is replaced with a electronic drain valve. The timer
is set to have ON time of 0.5sec and OFF time of 0.5min. Do not change this timer setting. If it is changed,
water could be discharged from the outlet line of the dryer.
Model
Item
IDU15E1-23-V
Part No.
IDF-S0198
Max. pressure
1.6MPa
Power supply voltage of drain timer
AC230V±10% (50Hz)
ON time
0.5sec
OFF time
0.5min
Specification for Option V
12