16-9-3

ZSE

ISE

PSE

Z

I

SE3

PS

Z

I

SE

1
2

ZSP

ISA2

IS

ZSM

PF2

IF

Data

Easy electrical wiring

Wide space for wiring. Fixed wiring possible with 

1

/

2

 connector.

Wide calibration range

0.1 to 0.7 MPa

High frequency operation and
long service life due to 
piston construction

High Frequency: 1 cycle/sec

Long service life: 10 million cycles

With indicator light (Option)

Model

Specifications

Model

Piping method

Rc 

1

/

thread

Gasket piping 

Rc 

1

/

thread

Gasket piping

IS3000-02

IS3100

IS3010-02

IS3110

Micro switch type

Standard

Min. applicable load

5 VDC 160 mA

Micro load

5 VDC 1 mA

Micro Switch Ratings

Air/Inert gas

1.0 MPa

0.8 MPa

0.1 to 0.7 MPa

–5 to 60

°

C (No freezing)

1ab

±

0.1 MPa

±

0.05 MPa

0.15 kg

Fluid

Proof pressure

Max. operating pressure

Pressure adjustment range

Ambient and fluid temperature

Contacts

Error of scale

Repeatability

Weight

Hysteresis

0.05 MPa or less

Model

0

0
1

Micro switch load type

With gasket

Rc 

1

/

4

NPT 

1

/

4

Nil

02

N02

Port size

How to Order

IS3  00

Inductive load (A)

Non inductive (A)

Non inductive (A)

IS3

Standard

Micro load

125 AC

250 AC

30 DC

125 DC

Load

Circuit

Rated 

voltage (V)

IS3  10

N.C.

Load resistance

Light load

Inductive load

Motor load

Load resistance

N.O.

N.C.

N.O.

N.C.

N.O.

N.C.

N.O.

N.C.

N.O.

5

3

4

   0.4

3

2

3

   0.4

0.1

0.1

1.3

0.8

2.5

1.5

0.7

0.5

   1.5

1

3

     0.05

2

     0.05

Insulation resistance: 100 M

 or more at 500 VDC by megameter

Voltage resistance: 1500 VAC,       Hz for 1 min. (When using switch with neon light: 1000 VAC for 1 min.)

50

/

60

None

With neon light/110 VAC

With neon light/220 VAC

LED/24 VDC

Nil

L1
L2
L5

Indicator light

0

0
1

Piping method

Rc 

1

/

thread

Gasket piping 

0

02

L1

Note) Micro load type: 
          Not available “L2” option.

0
1

0
1

IS3100
(Gasket piping)

IS3000-02
(Rc 

1

/

4

 thread)

IS3110
(Gasket piping)

IS3010-02
(Rc 

1

/

4

 thread)

JIS Symbol

Can be used for micro load, 
around 10 mA e.g. relays, pro-
grammable controllers, etc.

Pneumatic Pressure Switch

Series 

IS3000

For details about certified products 
conforming to international standards, 
visit us at www.smcworld.com.

Summary of Contents for IS3000 Series

Page 1: ...ch load type With gasket Rc 1 4 NPT 1 4 Nil 02 N02 Port size How to Order IS3 00 Inductive load A Non inductive A Non inductive A IS3 Standard Micro load 125 AC 250 AC 30 DC 125 DC Load Circuit Rated voltage V IS3 10 N C Load resistance Light load Inductive load Motor load Load resistance N O N C N O N C N O N C N O N C N O 5 3 4 0 4 3 2 3 0 4 0 1 0 1 1 3 0 8 2 5 1 5 0 7 0 5 1 5 1 3 0 05 2 0 05 In...

Page 2: ...following 2 Please put the enclosed seal of LAMP LIGHTS WHEN PRESSURE RISES or LAMP GOES OUT WHEN PRESSURE RISES on the equipment where it is easy to see 1 Allow the space required for maintenance Otherwise maintenance or pressure adjust ment cannot be made since the adjusting screw is on the top of the body 2 Mounting is possible in either horizontal or vertical orientations 1 Turn the adjusting ...

Page 3: ...d experienced operators 3 Do not service machinery equipment or attempt to remove components until safety is confirmed 1 Inspection and maintenance of machinery equipment should only be performed once measures to prevent falling or runaway of the driver objects have been confirmed 2 When equipment is to be removed confirm the safety process as mentioned above Cut the supply pressure for this equip...

Page 4: ... qualified personnel only 3 Drain flushing Remove drainage from air filters regularly Refer to the specifications 4 Shut down before maintenance Before attempting any kind of maintenance make sure the supply pressure is shut of and all residual air pressure is released from the system to be worked on 5 Start up after maintenance and inspection Apply operating pressure and power to the equipment an...

Page 5: ... an international standard related to environmental management systems and environmental inspections While promoting environmentally friendly automation technology SMC is also making diligent efforts to preserve the environment Environmental management system ISO 14001 Sales coordination Production Make customers our first priority offering them reliable and friendly service Market research Produc...

Page 6: ...achinery Directive The Machinery Directive contains essential health and safety requirements for machinery as applied to industrial machines e g machine tools injection molding machines and automatic machines Pneumatic equipment is not specified in Machinery Directive However the use of SMC products that are certified as conforming to EN Standards allows customers to simplify preparation work of t...

Page 7: ...ation OSHA SMC was tested for compliance with CSA Standards and UL Standards at the same time and was approved for compliance with the two Standards The above CSA NRTL C logo is described on a product label in order to indicate that the product is approved by CSA and UL Standards TSSA MCCR Registration Products TSSA is the regulation in Ontario State Canada The products that the operating pressure...

Page 8: ...6 COLOMBIA Distributor Airmatic Ltda Calle 18 69 05 Apart Aereo 081045 Santa Fe de Bogotá Colombia TEL 1 424 9240 FAX 1 424 9260 U K SMC Pneumatics U K Ltd Vincent Avenue Crownhill Milton Keynes MK8 0AN Backinghamshire U K TEL 01908 563888 FAX 01908 561185 GERMANY SMC Pneumatik GmbH Boschring 13 15 D 63329 Egelsbach Germany TEL 06103 4020 FAX 06103 402139 ITALY SMC Italia S p A Via Garibaldi 62 I ...

Page 9: ...Sylvia Park Road Mt Wellington Auckland New Zealand TEL 09 573 7007 FAX 09 573 7002 TAIWAN SMC Pneumatics Taiwan Co Ltd 17 Lane 205 Nansan Rd Sec 2 Luzhu Hsiang Taoyuan Hsien TAIWAN TEL 03 322 3443 FAX 03 322 3387 HONG KONG SMC Pneumatics Hong Kong Ltd 29 F Clifford Centre 778 784 Cheung Sha Wan Road Lai Chi Kok Kowloon Hong Kong TEL 2744 0121 FAX 2785 1314 SINGAPORE SMC Pneumatics S E A Pte Ltd 8...