Doc. no.IZ
*
-OMX0012
11
3.
W
iring
3-1.
AC adapter type/ IZG10-
□
01, 02
- Connect the M8 connector on the power cable for AC adapter to the power connector on the main unit.
Connect the outlet plug with the grounding terminal of the AC cord
Note)
to a commercial power outlet with
ground terminal (100 to 240VAC 50/60Hz).
- Connect the ground terminal correctly. The ground terminal is electrically connected to the frame ground
(F.G.) of the product. The F.G. maintains the static neutralizing performance by keeping its potential the
same as the reference potential.
- The input ground terminal and the output DC(-) terminal of the AC adapter (IZG10-CG1,2 ordered
separately) are electrically connected. Do not connect any equipment other than this product. Otherwise, a
failure or electric shock may result.
Ionizer
Power supply connector
Power supply cable (AC adapter)
AC adapter
AC adapter (with AC cord)
Outlet plug with
ground terminal
AC cord
(Not included with IZG10-
□
02)
Connection
Note) The rated voltage of the AC cord supplied with IZG10-
□
01 is 125V, and the plug is JIS C8303 type B, which is for
Japanese domestic use. If the product is used in an area other than rated voltage (220 or 240VAC), select IZG10-
□
02
without AC power cord and prepare an AC cord with ground terminal inlet IEC60320-C13 adapted to the power supply
voltage.
3-2. Power supply cable type/ IZG10-
□
03
- Route the external equipment for the power supply and external switch signal input prepared by the
customer according to the signal name on the power supply cable wiring table.
- Ground the green F.G. correctly. The static neutralizing performance is maintained by keeping its potential
the same as the reference potential.
Power supply connector
Ionizer
Connection
Power supply cable (24VDC)
Internal Circuit and Wiring Examples
主
回
路
+24V
+24V
INPUT
赤 DC(+ )
黒 DC(- )
DC24V
+
-
白 外部スイッチ信号
確実に接地
(接地抵抗100Ω以下)
緑 F.G.
Main unit
注)
Note) The external switch signal consists of a trigger input and an
OR circuit. When the external switch signal is not used, cut
the semi-strip processing section to prev ent the conductor
f rom making contact.
Power supply cable (24VDC)
Semi-stripped
3mm
Red
White
Green
Black
M
a
in
ci
rcu
it
Red DC
(
+
)
White
External switch signal
Note)
Green F.G.
Black DC
(
-
)
Ground correctly (Ground
resistance of 100
Ω or less)
24VDC
24VDC
24VDC
INPUT
Power supply cable wiring
Pin
No.
Signal name
Identification
colour
Description
1
DC(+)
Red
Connect the power ) of the product
2
External switch signal
Note)
White
Blow starts by connecting with DC(-)
3
F.G.
Green
Frame ground of the product
Ground resistance of 100
Ω or less
4
DC(-)
Black
Connect the power supply(-) of the product
Note) The external switch signal consists of a trigger input and an OR circuit. When the external
switch signal is not used, cut the semi-strip processing section to prevent the conductor from
making contact.
Pin No.
2
4
1
3