Doc. no.IZ
*
-OMX0012
12
4.
Function
4-1.
Name of parts
LED indication
(1)
(4)
(5)
(6)(7)
(8)
Inside of the slide cover
(3)
(2)
Name of parts
No.
Name
Description
(1)
Nozzle
Blows ionized air.
(2)
Slide cover
Protective cover for the mode setting switch.
(3)
Mode setting switch
Switch for setting blow and trigger. (Default setting: Setting No.0)
(4)
Flow rate adjustment handle
Adjust the flow by rotating the handle.
Rotation is locked by pushing the handle.
(5)
Trigger
Switch to turn on and off static neutralization.
(6)
One-touch fitting
Compressed air supply port.
(7)
Power supply connector
Connector to input the signal for power supply, F.G. Grounding and external switch.
(8)
Operation LED
Illuminate the object during static neutralization.
4-2. LED indication
(1)
(2)
(3)
LED indication
No.
Indication
Colour
Name
Description
(1)
PWR
Green
Power supply indicator
Green LED turns ON when power is supplied, and the LED
flashes when the voltage is outside of the specification range.
(2)
ION/HV
Green/Red
Ion emission/
high voltage error indicator
Green LED is ON during static neutralization.
Red LED is ON when a high voltage abnormality is present.
(3)
NDL
Green
Emitter maintenance indicator
Green LED is ON when the static neutralization performance
is reduced due to contamination or wear of emitters.