background image

 
 

Doc. no.IZ

*

-OMX0012 

 

18 

5-2.

 

Static neutralization range (Discharge time of 1000V

100V) 

- Mode setting switch: Continuous blow

 

Flow rate adjustment indicator (maximum) 

1)

2)

3)

4)

5)

6)

7)

Supply pressure 0.05 MPa
Consumed flow rate 80 L/min (ANR)

Supply pressure 0.1 MPa
Consumed flow rate 119 L/min (ANR)

Supply pressure 0.2 MPa
Consumed flow rate 188 L/min (ANR)

Supply pressure 0.3 MPa
Consumed flow rate 253 L/min (ANR)

Supply pressure 0.4 MPa
Consumed flow rate 316 L/min (ANR)

Supply pressure 0.5 MPa
Consumed flow rate 390 L/min (ANR)

Supply pressure 0.6 MPa
Consumed flow rate 450 L/min (ANR)

-200

-150

-100

-50

0

50

100

150

200

0

150

300

450

600

750

900 1050 1200 1350 1500

Distance  [mm]

2.5s

2s

1.5s

1s

0.5s

-200

-150

-100

-50

0

50

100

150

200

0

150

300

450

600

750

900 1050 1200 1350 1500

Distance

[mm]

2.5s

2s

1.5s

1s

0.5s

-200

-150

-100

-50

0

50

100

150

200

0

150

300

450

600

750

900 1050 1200 1350 1500

Distance

[mm]

1.5s

1s

0.5s

2s

-200

-150

-100

-50

0

50

100

150

200

0

150 300 450 600 750 900 1050 1200 1350 1500

Distance  [mm]

1.5s

1s

0.5s

-200

-150

-100

-50

0

50

100

150

200

0

150 300

450 600

750 900 1050 1200 1350 1500

Distance  [mm]

2.5s

2s

1.5s

1s

0.5s

-200

-150

-100

-50

0

50

100

150

200

0

150 300 450 600 750 900 1050 1200 1350 1500

Distance  [mm]

2s

1.5s

1s

0.5s

-200

-150

-100

-50

0

50

100

150

200

0

150 300 450 600 750 900 1050 1200 1350 1500

Distance  [mm]

1.5s

1s

0.5s

 

Summary of Contents for IZG10

Page 1: ...Doc no IZ OMX0012 1 PRODUCT NAME Ionizer Gun type MODEL Series Product Number IZG10 ...

Page 2: ...le type IZG10 03 11 4 Function 12 4 1 Name of parts 12 4 2 LED indication 12 4 3 Mode setting switch 13 4 4 Emitter maintenance cleaning and replacement 14 4 5 Alarm function 16 5 Performance 17 5 1 Installation distance and Discharge time Discharge time of 1000V 100V 17 5 2 Static neutralization range Discharge time of 1000V 100V 18 5 3 Pressure Flow characteristics 19 6 Dimensions 19 7 Specifica...

Page 3: ...f equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembly operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced 3 Do not service or attempt to rem...

Page 4: ...e failure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from this 1 year warranty A vacuum pad is a consumable part so it is warranted for a year after it is delivered Also even within the warranty period the wear of a product due to the use of the vacu...

Page 5: ...ment confirm the required cleanliness before use Fine particles are generated due to wear of emitters and motor sliding during operation 1 Before wiring ensure that the power supply capacity meets the specification and that the voltage is within the specification Product damage or malfunction can result 2 To maintain product performance the power supply should be UL Class 2 certified by National E...

Page 6: ...erformance and may also cause operation failure or an accident 12 If a valve is placed immediately before the product instantaneous air release may occur when compressed air is supplied regardless of the trigger operation of the product 13 If the supply pressure of compressed air is less than the product specification pressure 0 05MPa the valve in the product may not open or close Use the product ...

Page 7: ...o obtain clean compressed air air quality of Class 2 4 3 2 5 3 2 6 3 or higher according to ISO 8573 1 2010 JIS B8392 1 2012 is recommended for operation 7 The product and AC adapter are not resistant to lightening surge 8 Influence on the implantable medical equipment Electromagnetic waves emitted by this product may adversely affect implantable medical devices such as implantable cardiac pacemak...

Page 8: ...ric shock or fire The product will not be guaranteed if it is disassembled and or modified 6 Do not operate the product with wet hands It may cause electric shock or other accidents 1 Please check the following points in the regular maintenance and replace the parts as necessary a Emitter is dirty or worn out b Loosening or damage of the nozzle c Squeezing or twisting of the tubing that is connect...

Page 9: ...an Rated voltage 125V plug JIS C8303 inlet IEC60320 C13 The nozzle specified for the product Do not use other nozzles Otherwise static neutralizing performance will be adverselyaffected Nozzle One touch fitting 1 2 Accessories AC adapter IZG10 CG AC adapter Type With AC cordNote Without AC cord 2 Symbol 1 Note The AC cord is only for use in Japan Rated voltage 125V plug JIS C8303 inlet IEC60320 C1...

Page 10: ...ルト2個付属 2 How to Use 2 1 Procedures to operation Start Wiring of ionizer Compressed air supply Refer to 3 Wiring Air piping Power supply ON Completed Protection cap Remove when used Provided together with 1 felt pad grindstone 1 rubber grindstone and 2 replacement felt pads Provided together with 10 replacement felt pads Provided together with 1 replacement rubber grindstone ...

Page 11: ...2 Power supply cable type IZG10 03 Route the external equipment for the power supply and external switch signal input prepared by the customer according to the signal name on the power supply cable wiring table Ground the green F G correctly The static neutralizing performance is maintained by keeping its potential the same as the reference potential Power supplyconnector Ionizer Connection Power ...

Page 12: ... port 7 Power supply connector Connector to input the signal for power supply F G Grounding and external switch 8 Operation LED Illuminate the object during static neutralization 4 2 LED indication 1 2 3 LED indication No Indication Colour Name Description 1 PWR Green Power supply indicator Green LED turns ON when power is supplied and the LED flashes when the voltage is outside of the specificati...

Page 13: ...o 9 Blows ionized air intermittently Pulse frequency 5 Hz Trigger setting Trigger ON is enabled by inputting either the main unit trigger or external switch signal Trigger linked Set No 0 and No 5 Trigger ON OFF and blow ON OFF are linked Trigger locked Set No 1 and No 6 Blow ON is maintained when trigger operation is ON When the trigger operation is ON again the blow is OFF OFF timer Set No 2 to ...

Page 14: ...e emitters are touched while the product is energized this may cause an electric shock or accident Since the tip of the emitter is pointed there is a danger of injury if touched When replacing the emitter assembly use a tool such as pliers to avoid direct contact with the tip of the emitter Cleaning of the emitter Using the cleaning kit saturate the felt with industrial alcohol insert it into the ...

Page 15: ...assembly by rotating it as shown in the figure below with the protective cap attached Always remove the protective cap after mounting the emitter assembly Be careful when removing the cap as there is a danger of injury due to the emitter tip Hand tighten the nozzle in the direction shown below until it does not turn any more The recommended tightening torque by hand tightening is 0 1 to 0 2 N m St...

Page 16: ... power back on 2 Incorrect high voltage If the high voltage output drops during operation ION HV LED red turns ON to notify the error When the failure occurs ion generation will be stopped The decrease of high voltage output could be caused by abnormal discharge due to condensation or dust on the emitters In order to clear the alarm remedy the cause of the abnormality and supply power again 3 CPU ...

Page 17: ... 2 5 3 0 3 5 4 0 4 5 5 0 0 150 300 450 600 750 900 1050 1200 1350 1500 Discharge time sec Installation distance mm 0 05MPa 0 1MPa 0 2MPa 0 3MPa 0 4MPa 0 5MPa 0 6MPa 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 4 5 5 0 0 150 300 450 600 Discharge time sec Installation distance mm 0 05MPa 0 1MPa 0 2MPa 0 3MPa 0 4MPa 0 5MPa 0 6MPa Mode setting switch Pulse blow 5 6 7 8 Flow rate adjustment indicator 2 Flow ra...

Page 18: ... L min ANR 200 150 100 50 0 50 100 150 200 0 150 300 450 600 750 900 1050 1200 1350 1500 Distance mm 2 5s 2s 1 5s 1s 0 5s 200 150 100 50 0 50 100 150 200 0 150 300 450 600 750 900 1050 1200 1350 1500 Distance mm 2 5s 2s 1 5s 1s 0 5s 200 150 100 50 0 50 100 150 200 0 150 300 450 600 750 900 1050 1200 1350 1500 Distance mm 1 5s 1s 0 5s 2s 200 150 100 50 0 50 100 150 200 0 150 300 450 600 750 900 105...

Page 19: ...450 500 0 0 1 0 2 0 3 0 4 0 5 0 6 Flow rate L min ANR Supply pressure MPa Indicator maximum Indicator 7 Indicator 6 Indicator 4 Indicator 2 Indicator 0 6 Dimensions Ionizer IZG10 01 Power supply connector One touch fitting Applicable tube O D Table 1 Table 1 Applicable tube O D ø8 mm ø5 16 inch IZG10 08 01 IZG10 09 01 Models ...

Page 20: ...IZG10 CG2 Not included Models AC cord Power supply cable 24VDC IZG10 CP Power supply cable 24VDC Semi stripped terminal Cable specification 4mm Number of cable wire Size Sheath material O D Insulator outside diameter Identification colour Nominal cross section of the conductor 4pcs AWG26 0 15mm2 0 85mm Red Black White Green Lead free PVC ...

Page 21: ...d Directive CE Measurement values based on a charged plate dimensions 150 x 150 mm electrostatic capacity 20pF defined by ANSI standard ANSI ESD STM3 1 2015 Distance between charged plate and ionizer 150 mm Air purge 0 2 MPa Model Ion generation method Method of applying voltage Applied voltage Note 1 Air Clean dry air Offset voltage Note 2 Power supply voltage Current consumption Ambient temperat...

Page 22: ...ve the problem of the entry of foreign matter into the nozzle and turn on the power again NDL alarm output Main unit LED display Discharge amount is reduced due to foreign matter adhering to the emitter or wear of the emitter Replace the emitter when repeatedly outputting an alarm while performing maintenance on the emitter Insufficient blow Air source flow rate adjustment Insufficient amount of b...

Page 23: ...da Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer 2020 SMC Corporation All Rights Reserved ...

Reviews:

Related manuals for IZG10