Doc. no.IZ
*
-OMX0012
5
1) This product is intended to eliminate static electricity from general factory automation equipment.
If considering using the product for other applications (especially those indicated in (4) on page 3), please
consult SMC beforehand.
2) Do not operate beyond the specifications.
If the product is used outside of the specifications, it may cause malfunction, failure or damage to the product,
leading to an electric shock, explosion or fire.
3) Use the product within the operating temperature, humidity and fluid temperature.
Malfunction, failure, or damage to the product can result. Even within the specification range, freezing and
condensation can cause malfunction, failure, or damage in environments where sudden temperature
changes and temperature cycles are applied.
4) Use within the specified voltage range.
Operation with a voltage other than that specified can cause malfunction, damage to the product, electric
shock or fire.
5) Use clean compressed air as fluid. (Air quality Class 2.6.3 specified in ISO 8573-1: 2012 is
recommended.)
Never use flammable gas or an explosive gas as a fluid and never use this product in the presence of such
gases. This may lead to fire or explosion. Please contact SMC if using for fluids other than compressed air.
6) This product is not designed to be explosion proof.
Never use in an atmosphere of potentially explosive dust, flammable gas or explosive gas. Fire or an
explosion can result.
1) Clean room specification is not available.
When using in a clean room environment, confirm the required cleanliness before use.
Fine particles are generated due to wear of emitters and motor sliding during operation.
1) Before wiring, ensure that the power supply capacity meets the specification and that the voltage is
within the specification. Product damage or malfunction can result.
2) To maintain product performance, the power supply should be UL Class 2 certified by National Electric
Code (NEC) or evaluated as a limited power source according to UL60950.
3) The supply of power and compressed air must be stopped before wiring (including insertion and
removal of the connector). Otherwise, an electrical shock or accident may occur.
4) To maintain the product performance, connect the product to ground with an earth cable or AC
adapter ground terminal with a resistance of 100
Ω or less. If the product is not grounded, it is not
possible to secure the performance and may lead to product failure or malfunction.
5) If the power and high voltage cables are routed together, the product may malfunction due to noise.
Route the Ionizer wires separately.
6) Flush the piping before connecting. Before piping this product, exercise caution to prevent particles,
water drops, or oil contents from entering the piping.
7) If a valve is placed immediately before the product, instantaneous air release may occur when
compressed air is supplied regardless of the trigger operation of the product.
8) Confirm that the wiring and piping are correct before supplying power and compressed air. Incorrect
wiring and piping will lead to product damage or malfunction.
9) Ensure the safety of wiring and piping around the product before supplying power and compressed
air.
Warning
Warning
Caution
Selection
Wiring and Piping