1) Mount the designated nozzle to the product.
2) Confirm that the nozzle is not loose or does not have play before supplying compressed air. When the
nozzle is loose, tighten it by hand until it does not rotate (guideline of the tightening torque by hand:
0.1 to 0.2 N·m) Static neutralizing performance is deteriorated when the nozzle is loose.
3) Be sure to wear safety goggles to protect the eyes from splashed substances.
4) Do not direct the tip of the nozzle at the face or any other parts of the human body.
It may cause injury to personnel.
5) Do not use the product to clean or remove toxic substances or chemicals.
6) Do not drop, step on or hit the product. Otherwise, the product may be damaged.
7) If product is to be used in a public place, ensure product is not directed at people or used in a manner
that could adversely affect the environment.
8) This product is not a toy.
9) After blowing, be sure to hang the product on a hook, etc.
10)
Make sure that no twist, turn, tensile force or moment load is applied to the one-touch fitting, tube and
power cable during use or storage. It may lead to damage or broken wire.
11) Do not allow foreign matter or tool to enter the ionizer nozzle.
The emitter is installed in the nozzle. If conductive objects such as metal tools or the human body either
contacts or comes close to the emitter, reaction to electric shock can lead to further injuries due to collision
with surrounding equipment. Also, if the tool damages the emitters, it may interfere with the specified
function and performance, and may also cause operation failure or an accident.
12)
If a valve is placed immediately before the product, instantaneous air release may occur when
compressed air is supplied regardless of the trigger operation of the product.
13) If the supply pressure of compressed air is less than the product specification pressure (0.05MPa), the
valve in the product may not open or close. Use the product with the supply pressure within the
product specification value.
1) Do not use this product in an enclosed space.
This product utilizes the corona discharge phenomenon. A small amount of ozone and NOx will be generated.
When the product is used in an enclosed space where ozone concentration increases, the smell of ozone
may be uncomfortable or aggressive. Even when the room is not an enclosed space, ozone concentration
increases when multiple products are used in a small space. The operating environment must always be
ventilated.
2) Take prevention measures against ozone.
Check that all surrounding equipment have ozone protection measures in place. Perform periodic checks of
the product for deterioration caused by ozone.
3) Supply compressed air when the product is in use.
Static neutralization is not possible without supplying compressed air. Without compressed air, the ozone
or NOx generated by ion generation will stagnate and give adverse effects on the product or peripheral
equipment.
Warning
Warning
Handling
Operating / Storage Environment
High voltage is applied to the emitters. Never touch the electrodes.
Touching electrode may cause electrical shock and instantaneous
rapid body motion to escape from the shock. Your body may then
touch the equipment around you, causing injury.
Nozzle
One-touch fitting
Danger High voltage