Doc. no.IZ
*
-OMX0012
21
7.
Specifications
Ionizer
Note 1)
Value measured with probe of 1,000MΩ and 5pF.
Note 2)
Note 3) Static neutralization is not possible without supplying compressed air. Without compressed air, the
ozone or NOx generated by ion generation will stagnate and give adverse affect on the product or
peripheral equipment.
24VDC +/-10% (21.6 to 26.4V)
90mA (typ.)
0 to 40
o
C (No freezing)
35 to 65%Rh (No condensation)
Weight (Body)
200g
Material
Case
:
PBT
Emitter
:
Tungsten
Ambient humidity
0.05 to 0.6MPa
ø8(mm), ø5/16” (inch)
IZG10
Corona discharge
High frequency AC type
+/-2.5kV
/-10V
Standard / Directive
CE
Measurement values based on a charged plate (dimensions: 150 x 150 mm, electrostatic capacity:
20pF) defined by ANSI standard (ANSI/ESD STM3.1-2015). Distance between charged plate and
ionizer: 150 mm, Air purge: 0.2 MPa.
Model
Ion generation method
Method of applying voltage
Applied voltage
Note 1)
Air (Clean dry air)
Offset voltage
Note 2)
Power supply voltage
Current consumption
Ambient temperature
Air purge
Note3)
Fluid
Operating pressure
Connected tube O.D.
AC adapter
Note 1)
Applicable standard/directive
CE cUL
AC cord for IZG10-CG1 is only for use in Japan (Rated voltage: 125V, Plug: JIS C8303, Inlet:
IEC60320-C13).
Model
IZG10-CG
□
100 to 240VAC, 50/60Hz
24VDC +/-5%
0 to 40
o
C
20 to 80%Rh
Input voltage
Note 1)
Output voltage
Output current
Ambient temperature
Ambient humidity
0.8A max