10
1) Do not apply excessive external force or shock (100m/s2 or more) to the product
·
Even if the there are no problems with the appearance of the controller, high voltage power supply module or
bar, the damage of the internal components may cause malfunction.
2) When the bar length exceeds 820mm, hold the both ends and the middle of the bar so that moment
load is not applied.
·
Handling the product by holding either end of the bar may cause deformation or damage to the product.
3) Power cable must be connected and disconnected by hand.
·
Open and close too much may damage the drain cock.
·
Hold the connector by hand and straightly pull it out.
·
If the connector has lock mechanism, release the lock and then pull out the connector.
4) If smoking, fire or smell occurs in the product, immediately shut off the power supply.
5) Do not touch the A part of the high voltage connector by hand. Be careful so that moisture or foreign
matter does not adhere to the connector.
·
Do not touch the A part of the high voltage connector by hand while handling.
·
Keep the high voltage connector free from contamination. Adhesion of oil or foreign matter on the A part
may cause high voltage electric leakage.
·
If moisture, oil, or foreign matter adheres to the A part, clean it with ethanol.
Caution
Handling
High voltage connector
(Back)
A
A