20
Start
Installation of ionizer body
Wiring of ionizer
Air purge
Piping of ionizer
Pressure setting
Initial setting
Adjustment of offset voltage
(ion balance)
Completed
High voltage power supply
module CH number setting
Yes
No.
Power supply is ON
Frequency setting
2. Procedures to Operation
2-1. Flow chart to operation
2-2. Initial setting (Initial setting is not necessary for IZT40)
·
This product has a function which constantly monitors the emitter contamination. When emitter
contamination is detected, it is indicated by a signal output and LED. Initial setting is necessary for
maintenance detection.
·
In the default setting "
no
" is displayed for the frequency display.
·
The Initial setting is started by pressing the S button for 3 seconds or longer while "
no
" is displayed. To
revert to the default setting press the reset button during use.
·
Connect and install the ionizer bar to be used before setting.
·
When multiple bars are connected, assign the channel for which initial setting is necessary.
Refer to 4-4-2. Channel selection mode for channel setting.
·
Do not disconnect the power supply during setting. (Initial setting is completed within 60 seconds.)
[Initial setting is necessary in following cases]
①
When "
no
" is displayed in the frequency display.
②
Bar is replaced.
③
Installation environment is changed.
※
For
②③
, perform initial setting after pressing the reset button
and make sure that "
no
" is displayed in the frequency display.
It is recommended to start the initial setting for
③
after replacing
the emitter cartridge. If initial setting is performed while the emitter
cartridge is not clean or is worn out, maintenance detection may not
work properly.
Refer to 3-1. Installation of Ionizer for details.
Refer to 3-2.Wiring.
Refer to 3-1. Installation of Ionizer for details.
Caution: Do not adjust the flow using the restrictor.
Refer to 3-1-2. Adjustment of Pressure (Flow adjustment).
Refer to 4-3. High voltage power supply module CH number setting.
Refer to 4-4-3. Frequency set mode.
Refer to 4-4-4. Adjustment mode of Offset Voltage
Refer to 2-2.Initial setting.(
Initial setting is not necessary for IZT40)
Controller
(IZTC41)
Frequency
display
Summary of Contents for IZT40 Series
Page 1: ...Document No IZ OMT0049 B PRODUCT NAME Ionizer MODEL Series IZT40 41 42series...
Page 73: ...High voltage power supply module IZTP40 IZTP41 When DIN rail mounting bracket IZT40 B2 is used...
Page 74: ...High voltage power supply module IZTP42 When DIN rail mounting bracket IZT40 B3 is used...