43
4. Function
4-1. Name of Parts
4-1-1. Controller
1)IZTC40
Note51) Refer to [4-4. Controller setting] or [4-5-1. Alarm for IZT40] for details of frequency.
9
10
1
6
5
7
2
3
4
8
Table11. Name of parts
No.
Name
Panel
indication
Type
Description
1
CH display
CH
LED
(Green)
High voltage power supply module connected to the controller is ON (green).
Flashes (green) when selecting frequency or adjusting the offset voltage.
2
Frequency display
Hz
LED
(Green)
Green LED is ON during operation.
Green LED flashes during frequency selection, adjustment of the offset voltage and abnormality exists.
Note 51)
3
Ion emission/
high voltage error display
ION/HV
LED
(Green /
Red)
Green LED is ON during static neutralization.
Red LED is ON when high voltage abnormality exists.
LED flashes (red) when CPU abnormality (controller/ high voltage power supply module),
power supply abnormality, communication error, cooling fan motor failure, module inconsistency,
or CH duplication exists.
Turned off when the high voltage power supply module is not connected.
4
Key-lock display
KEY
LED
(Green)
Key lock ON : ON (green)
Key lock OFF : OFF
5
▼
button
-
Press button Decrease the set value.
6
S button
-
Press button Change the mode and set a set value.
7
▲
button
-
Press button Increase the set value.
8
Reset button
-
Press button Return the setting values of each mode to the default condition.
9
Power supply connector
-
Connector
Equipped with ionizer power supply and grounding.
10
High voltage power supply
module connector
-
D-sub
connector
(socket)
Connect high voltage power supply module or separate cable.
Summary of Contents for IZT40 Series
Page 1: ...Document No IZ OMT0049 B PRODUCT NAME Ionizer MODEL Series IZT40 41 42series...
Page 73: ...High voltage power supply module IZTP40 IZTP41 When DIN rail mounting bracket IZT40 B2 is used...
Page 74: ...High voltage power supply module IZTP42 When DIN rail mounting bracket IZT40 B3 is used...