Saturate the felt end of the emitter cleaning tool with alcohol
and insert it into the back of the emitter cartridge. Turn the
tool for several rotations to thoroughly remove dirt.
·
If it is not possible to thoroughly remove the dirt using the
felt end of the cleaning tool, the rubber-bonded whetstone
should be used in the same procedure as described for that
of the felt end.
·
If you do not have a cleaning kit, an alcohol saturated cotton
ball can be used for cleaning the electrodes. Use caution to
prevent damage to the electrode needles.
·
The alcohol used should be reagent ethanol class 1
99.5vol% or more.
d. When the emitter cartridges are removed for cleaning, remount them to the ionizer according to the
"Mounting procedure of emitter cartridge" shown below. Make sure that the cartridges are securely
mounted. If not, the cartridges may become dislodged when compressed air is supplied to the ionizer.
e. Confirm that the static neutralization performance is maintained after cleaning and remounting of the
cartridges are completed.
Replacement of the felt or rubber-bonded whetstone tips of the emitter cleaning kit
·
The felt or rubber-bonded whetstone tips of the emitter cleaning kit should be replaced referring to the
procedure below when it becomes dirty, as it will not sufficiently clean the emitter.
a.
Remove the felt or the rubber-bonded whetstone tip at the end of the emitter cleaning kit.
b. Insert a new felt or rubber-bonded whetstone tip into the emitter cleaning kit using the reverse
procedure as the removal. The felt and the rubber-bonded whetstone tips are rectangular, and the
inserting orientation is specified. The end of the rubber-bonded whetstone tip will stick out of the
emitter cleaning kit end for 1mm. Do not push it in too much.
Description
Part No.
Qty.
Replacement felt pad
IZS30-A0201
10
Replacement rubber grindstone
IZS30-A0202
1
Emitter cleaning kit
Part number for spare felt/ rubber-bonded whetstone tips
Mounting of the emitter cartridge
(1) Insert the cartridge into the bar so that
the longer side of the cartridge is mounted
at a right angle to the bar.
2) Rotate the cartridge 90 degrees to
match the markings on the bar to
those on the cartridge and secure.
Cleaning kit with
rubber-bonded whetstone
Cleaning kit with felt
Removing the felt