6 Utility Functions (Fn
口口口
)
6-4
6.3 JOG Operation (Fn002)
JOG operation is used to check the operation of the servomotor under speed control without connecting the
DRIVER to the host controller.
CAUTION
While the DRIVER is in JOG operation, the overtravel function will be disabled. Consider the operating
range of the machine when performing JOG operation for the DRIVER.
(1) Preparation
The following conditions must be met to perform a jog operation.
The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
The main circuit power supply must be ON.
All alarms must be cleared.
The hardwire baseblock (HWBB) must be disabled.
The servomotor power must be OFF.
The JOG speed must be set considering the operating range of the machine. Set the jog speed in Pn304.
Pn304
Jog Speed
Speed
Position
Torque
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
0 to 10000
1 min
-1*
500
Immediately
Setup
(2) Operating Procedure
Use the following procedure. The following example is given when the rotating direction of servomotor is set as
Pn000.0=0 (Forward rotation by forward reference).
1. In the S
Σ
-V component main window, click
Test Run
, and then click
Jog
.
2. Set up the JOG speed. To change the JOG speed, click
Edit
.
3. Click
Servo ON
.
4. Press
Forward
or
Reverse
. A JOG operation is performed only while one of these buttons is pressed.
For more information on the usage of the S, refer to AC Servo Drives Engineering Tool Sigma Win+
ONLINE MANUAL Σ-V Component
4.7.1 JOG Operation
.
Summary of Contents for LECYU Series
Page 30: ...1 Outline 1 9 1 4 3 Three phase 200 V LECYU2 V9 Models ...
Page 65: ...3 Wiring and Connection 3 11 3 Wiring Example with DC Power Supply Input DRIVER ...
Page 92: ...3 Wiring and Connection 3 38 External Dimensions Units mm 1 FN Type by Schaffner EMC Inc ...
Page 93: ...3 Wiring and Connection 3 39 2 FN Type ...
Page 143: ...4 Operation 4 44 ...