6.7 Clearing Alarm History (Fn006)
The clear alarm history function deletes all of the alarm history recorded in the DRIVER.
Note: The alarm history is not deleted when the alarm reset is executed or the main circuit power supply of the DRIVER is
turned OFF.
(1) Preparation
The follow conditions must be met to clear the alarm history.
The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
(2) Operating Procedure
Use the following procedure.
1. In the S Σ-V component main window, click
Alarm
and then click
Display Alarm
.
2. To clear an alarm, click
Reset
after removing the cause of the alarm.
For more information on the usage of the S, refer to AC Servo Drives Engineering Tool Sigma
Win+ ONLINE MANUAL Σ-V Component
4.2
Alarm Display.