Document No.ZL-OM01001
- 10 -
Mounting and Installation
1. Tighten the body to the recommended tightening torque (For top and side mounting: 1.2 to
1.5N
・
m, for bottom mounting: 0.60 to 0.74 Nm ).
If the recommended tightening torque is
exceeded, the body, mounting screws and brackets may be damaged. Insufficient torque can
cause displacement of the body from its proper position and the looseness of the mounting
screws.
2. If air leakage increases or the equipment does not operate properly, stop operation. After
installation and maintenance, apply air and power supplies to the equipment and perform
appropriate functional and leakage inspections to make sure the equipment is mounted
properly.
3. Do not drop, hit or apply excessive shock to the product. The inner parts can be damaged
leading to malfunction even if the sensor body is not damaged.
4. Mount the product in a location that is not affected by vibration or impact.
Failure and malfunction can occur.
5. Do not fix the product such that a load is always applied to the air pressure supply port, vacuum
port, vacuum pressure detection port and exhaust port in a bending or pulling direction. This
can damage this product.
6. Do not pull the lead wire forcefully, or lift the product by the lead wire (Lead wire tensile
strength: within 30N). Hold the product body when handing.
7. Do not obstruct the exhaust port of the ejector. Do not cover the exhaust port. Otherwise,
vacuum is not generated. Do not block the exhaust port to release the work piece. This can
damage the vacuum ejector
.
8. If the product is operated in a dusty environment or if there is dust on the surface of the work
pieces, it can cause clogging of the silencing material as well as the suction filter. Secure
space necessary for the maintenance checks and replacement of the silencer when the ejector
performance decreases.
9. Be sure to connect the ground terminal F.G. to ground when using a commercially available
switch-mode power supply.
10. Although this product is interchangeable with the ZL112 multistage ejector (old product),
adapter assembly for bottom porting (ZL112A-AD1-A) is required only for the bottom porting.
When the adapter assembly for bottom porting is
mounted to the product, please follow the
direction specified on the right side.
(Recommended tightening torque:
0.60 to 0.74 Nm)
Adapter assembly
for bottom mounting