6.2
Change to 1 cup (without flange)
1. Removal of the cup mounting flange
(1) Loosen the bolt (M6 x 12), then remove the cup mounting flange.
Be careful not to lose the O-ring.
(2) Remove the parallel pin.
2. Mounting of the cup with adapter
(1) Remove the cup with adapter from the flange with cup removed in the process 1 above.
(2) Confirm the gasket seal in the adapter, then mount the cup with adapter removed in the process (1) to
the product.
Reassemble the parts by reversing the disassembling process with specified tightening torque.
Caution
T
ightening torque: 1N
・
m, (As reference, tighten by 45 degrees using a spanner after tightening by hand))
If tightened excessively, thread portion may be damaged and gasket may be deformed. This will cause air
leakage. Insufficient tightening may loosen the thread or cause air leakage.
Hexagon socket head cap screw (M6x10)
Tightening torque 5.2N
・
m
Cup mounting flange
Parallel pin
Suction cup with adapter
(1) Disassemble the cup mounting flange
(2) Mounting a suction cup with adapter
Suction
cup with
adapter
Completion drawing