8 Liquid gas – G30/31 - 30/37 mbar
AUX
SR
R
DUAL int + ext
Rated heating capacity (kW)
1.0
1.75
2.9
4.2
Nozzle diameter (1/100 mm)
50
65
85
46 + 91
Pre-chamber (printed on nozzle)
-
-
-
-
Reduced flow rate (W)
400
500
800
1900
Rated flow rate G30 (g/h)
73
127
211
305
Rated flow rate G31 (g/h)
71
125
207
300
9 LPG G30/31 - 37 mbar
AUX
SR
R
DUAL int + ext
Rated heating capacity (kW)
1.0
1.8
2.9
4.2
Nozzle diameter (1/100 mm)
50
65
81
46 + 85
Pre-chamber (printed on nozzle)
-
-
-
-
Reduced flow rate (W)
450
550
800
1900
Rated flow rate G30 (g/h)
73
131
211
305
Rated flow rate G31 (g/h)
71
129
207
300
10 LPG G30/31 - 50 mbar
AUX
SR
R
DUAL int + ext
Rated heating capacity (kW)
1.0
1.8
2.9
4.2
Nozzle diameter (1/100 mm)
43
58
70
43 + 70
Pre-chamber (printed on nozzle)
(H2)
(M)
(Z)
(H2) + (S1)
Reduced flow rate (W)
400
500
800
1900
Rated flow rate G30 (g/h)
73
131
211
305
Rated flow rate G31 (g/h)
71
129
207
300
11 Town gas G110 – 8 mbar
AUX
SR
R
DUAL int + ext
Rated heating capacity (kW)
1.0
1.8
2.8
3.7
Nozzle diameter (1/100 mm)
145
185
260
140 + 320
Pre-chamber (printed on nozzle)
/8
/2
/3
-
Reduced flow rate (W)
400
500
800
1400
12 Town gas G120 – 8 mbar
AUX
SR
R
DUAL int + ext
Rated heating capacity (kW)
1.1
1.8
2.9
3.8
Nozzle diameter (1/100 mm)
145
185
260
130 + 290
Pre-chamber (printed on nozzle)
/8
/2
/3
-
Reduced flow rate (W)
400
500
800
1400