Instructions for the installer
15
4.1
Adjustment of minimum for natural gas
Light the burner and take it to the minimum
.
Remove the gas tap knob and turn the
adjustment screw inside or at the side of the tap
shaft (depending on the model) until there is a
regular minimum flame. Replace the knob and
check burner flame stability: (rapidly turning the
knob from maximum to minimum position, the
flame should not go out). Repeat the operation on
all the gas taps.
4.2
Positioning and levelling of the appliance
Having carried out the electricity and gas hook-up, level the appliance
using the four adjustable legs.
4.3
Mounting the rear top upstand
•
Position the upstand above the top, taking care to align holes A with
holes B.
•
Secure the upstand to the top by tightening screws C.