Instructions for the Installer

BURNER, NOZZLE AND GAS CONSUMPTION DATA TABLES

Burner

Rated 

heat 

capacity 

(kW)

Bottled gas – G30/G31  30/37 mbar

n. turns 

by-pass

Nozzle 

diameter

1/100 

mm

By-pass

1/100 

mm

Reduced 

heat 

capacity

(W)

Capacity

g/h G30

Capacity

g/h G31

Left

4.5

closed

100

85

2200

327

321

Central 
(BQ90T)

4.5

closed

100

85

2200

327

321

Right

4.5

closed

100

85

2200

327

321

Radiant grill

3.8

1 + 1/4

95

Adj.

2500

276

271

Radiant grill 
(BQ90T)

4.5

1 + 1/4

105

Adj.

2700

327

321

Ultrarapid 
(BQ6030T)

3.5

closed

94

65

1500

254

250

In the 

by-pass n. of turns

 column, 

closed

 means fully screwed down.

Burner

Rated heat 

capacity 

(kW)

Natural gas - G20 20 mbar

n. turns 

by-pass

Nozzle diameter

1/100 mm

Reduced heat 

capacity

(W)

Left

4.5

1 + 1/4

150

2200

Central (BQ90T)

4.5

1 + 1/4

150

2200

Right

4.5

1 + 1/4

150

2200

Radiant grill

3.8

2

145

2500

Radiant grill (BQ90T)

4.5

2 + 1/2

155

2700

Ultrarapid (BQ6030T)

3.5

1

133

1500