Cleaning and maintenance
97
EN
10. When the appliance has finished taking
in the solution, shake the tube to remove
any residual liquid.
11. Return the tube to its original position,
remove the container of solution and
close the door.
12. Press the confirmation knob to start the
reservoir cleaning process. The display
will show the remaining time in the
cleaning cycle, alternating with the
message .
When the cleaning process is complete, a
buzzer will sound and the messages
and
will flash
on the display to request draining of the
solution.
13. Remove the cover from the evaporation
tray and dry it with the sponge supplied.
14. Insert the supplied sponge into the
evaporation tray.
15. Press the confirmation knob to begin
draining the residual solution from the
reservoir.
When the door is closed, an
automatic system will automatically
draw in any residual solution in the
tube to avoid drips.
Note: The evaporation tray cover
may be very hot: use appropriate
protection.