background image

32

Revision n° 2

User manual DEMI-One

Editing: 03/2009

INSTRUMENTS

MAINTENANCE ISTRUCTIONS FOR THE SAFETY VALVE

(WATER BLOCK®)

WATER BLOCK (WB) SAFETY VALVE

Indispensable device for washing machines, dishwashers and demineralizers as, under the conditions defined in the technical features 
herewith described, it prevents a flow of water greater than the one for which it has been set by the adjustment pointer. This avoids 
continuous leaking. The Water Block also has a particular non-return valve (antipollution). The device should be installed vertically (see 
fig. 2) and following the instructions carefully.

TECHNICAL FEATURES

-  

Burst pressure: 500 N/cm²

-  

Max. static pressure: 100 N/cm²

-  

Max. controllable volume: about 50 lt.

-  

Min. operating capacity: 2 lt/min.

-  

Max. operating capacity: 30 lt/min

-  

Max. water temperature: 70° C

USER INSTRUCTIONS

WATER BLOCK should be installed between the tap and the supply hose of the demineralizer (fig. 2). Using the enclosed plastic key, 
turn pointer ‘P’ (fig. 1) anticlockwise to the required setting (example, position 1,5).

CAUTION:

For use on other fixtures, set the pointer to a position suitable for that particular application, considering that each number on the scale 
corresponds to a controlled volume of approx. 4-6 litres. In case of installation on fixtures which foresee dispensing of drinking water  
for alimentary use it is advisable to let flow at least 10 litres of water inside the device before the connection, so as remove eventual 
impurities banked during the storage.

INSTALLATION

1.  

Manually screw the WB to the tap having suitable thread (3/4” gas), inserting the filter    

 

‘E’ with its convex side facing upwards (fig. 2). The WB will not operate properly if the

 

 filter is not installed correctly. If the WB is tightened or loosened with the aid of a 

 

wrench, the same must be applied to the appropriately octagonally shaped part of the   

 

housing ‘A’.

2. 

 Screw the supply hose ‘C’ to the lower end of the WB. If the supply hose is equipped 

 

with a filter, the latter must be substituted by a flat rubber washer ‘F’. If the said hose 

 

has to be tightened or loosened with the aid of a wrench, the same must be applied to 

 

the appropriately octagonally shaped part of the WB housing ‘B’ so as to hold it firmly 

 

while performing this operation. If a failure occurs causing a continuous water leak, 

 

the WB will shut off when the volume of water flowing through equals the amount to 

 

which it was previously set with the pointer ‘P’. To reset the Water Block again after 

 

it has shut off, turn the tap off and carry out the necessary repair work. Remove the 

 

supply hose ‘C’ from the Water Block and press the coloured plunger ‘H’ which is 

 

located inside the lower housing of the device itself (fig. 1). It may be difficult to press 

 

this plunger if there is high pressure at the inlet side of the WB. In this case, slacken the 

 

device from the tap: the plunger ‘H’ can then be pressed with ease. Repeat the 

 

operation as described in the section headed ‘Installation’.

CAUTION:

To avoid any possible damage that may be caused by water freezing inside the WB after its 
installation, the ambient temperature should never be below 2° C. We decline all responsibility 
deriving from the incorrect use of the WB or from its use for applications and/or solutions not 
expressly foreseen by the above instructions.

MAINTENANCE:

Depending on the conditions and frequency of usage of the water block, it is recommended to clean out the inlet filter ‘E’
periodically and to replace the seal ‘F’.We reserve the right to modify any features without prior notice.

Summary of Contents for DEMI-ONE

Page 1: ...DEMI One INSTRUMENTS...

Page 2: ...zer correctly it is necessary to read this manual carefully All our products comply with the current safety norms and do not involve any risk for the operator when used according to the instructions p...

Page 3: ...RY CONTENT 24 INSTALLATION AND USE 25 SYMBOLS ON THE NAMEPLATE 25 MOUNTING OF THE RESIN CARTRIDGES 26 INSTALLATION 27 REPLACEMENT OF THE RESIN CARTRIDGES 28 PRECAUTIONS TO AVOID WATER CONTAMINATION 28...

Page 4: ...this manual Only use genuine manufacturer resin cartridges dedicated for this product Do not drink the water produced by DEMI One Do not block or crush the inlet or outlet pipes of the equipment or th...

Page 5: ...ial is spilled People precautions Keep people away from the area of spillage Resin beads on the floor may cause floor to be slippery Take care not to slip Cleaning methods Sweep the floor and transfer...

Page 6: ...ertificates Please request special transport packaging if this is not available Services under warranty are provided by the distributor or indirectly by its contractual partners We accept no responsib...

Page 7: ...he condition of the package and keep it in case of future needs Open the package and check that the contents correspond to the delivery note there is no evidence of any damage In the event of damage o...

Page 8: ...Item Description 1 Demineralizer 2 2 resin cartridges 2 sealing rings 3 Special key to replace cartridges 4 Water inlet tube 4m 6x4 mm 5 Water Block valve including filter and setting key 6 Water gun...

Page 9: ...ressure 1 5 bar SN 90000D0010 Smeg SpA Via L da Vinci 4 Made in EU Model name Tap water pressure Manufacturer Read the manual carefully CE label Product code Serial number Recycling symbol Country of...

Page 10: ...he use of the supplied special key Insert the two new cartridges 4 Place the cartridge seals on the upper face side of the resin cartridges 5 Place the o rings in the groove of the resin cartridge hol...

Page 11: ...be to the security valve and the demineralizer 3 Connect the spiral tube to the front of the demineralizer WARNING Use only original spare parts The Water Block valve is fitted with a special one way...

Page 12: ...ed for a longer period of time OPERATION OF THE DEMINERALIZER Once installed and fitted correctly the demineralizer is able to supply demineralized water immediately ATTENTION The demineralizer is equ...

Page 13: ...how often the demineralizer is used REGULAR CHECK OF THE WATER BLOCK AND ONE WAY VALVES ATTENTION To ensure compliance with subsection 4 6 of EN1717 have the Water Block and the one way valve checked...

Page 14: ...ER HEAD COVER 2 FILTER HEAD 3 CARTRIDGE HOLDER 4 RESIN CARTRIDGE KIT 4 CARTRIDGES 4 SEALING RINGS 4 O RINGS 5 PLASTIC KEY FOR CARTRIDGE HOLDER 6 WATER GUN 7 SPIRAL TUBE 8 TAP 9 WATER TUBE 4 m 6X4mm 10...

Page 15: ...irect sunlight and all sources of heat Size WxDxH 305x190x320 mm LxPxH Weight without cartridges 2 8 Kg Weight of two cartridges 1 5 Kg Tap water pressure range 1 5 bar Amount of demineralized water p...

Page 16: ...ate properly if the filter is not installed correctly If the WB is tightened or loosened with the aid of a wrench the same must be applied to the appropriately octagonally shaped part of the housing A...

Page 17: ...s smeg it www smeg instruments com Our Sales Department will inform you about prices and sales offers You can also visit our website in order to see the complete range of products Our Assistance depar...

Page 18: ...Smeg SpA via L da Vinci 4 Instruments Division via Circonvallazione 36 42016 Guastalla RE Tel 39 0522 8211 Fax 39 0522 821 592 E mail instruments smeg it www smeg instruments com...

Reviews: