Instructions for Use

Tumble Dryer

Summary of Contents for DRY72BK

Page 1: ...Instructions for Use Tumble Dryer ...

Page 2: ...ct the environment dispose of your appliance by delivering it to the authorized dealer The appliance is intended exclusively for use in households If the appliance is used for professional purposes for profit or for purposes beyond regular use in a household or if appliance is used by a person who is not a consumer the warranty period equals the shortest warranty period possible as stipulated by t...

Page 3: ...cated under the door frame Technical data depending on model Dimensions of the appliance w x d x h 600 mm x 600 mm x 850 mm Weight net evacuation dryer 33 kg condensation dryer 38 kg 40 kg depending on model Nominal voltage 230 V 50 Hz Connecting power 2500 2800 W depending on model Max load 6 kg 7 kg Connection power cord 230 V 50 Hz min 16 A Fuse 16 A Heater 2300 2500 W depending on model 3 Appl...

Page 4: ...liance is located must be well aired to prevent back flow of gasses released by open fire gas appliances fireplace The warranty shall not apply to consumables bulbs minor discoloration or deviations of color increased noise level as a consequence of appliance age which does not affect appliance functionality and aesthetical deficiencies which do not affect appliance functionality or safety To redu...

Page 5: ...ut any threat to the environment To be able to do this effectively all materials are marked accordingly Be careful not to damage cabinet of the appliance with a sharp object when removing the packaging Before connecting the appliance let it warm up to room temperature wait for two hours Ventilation slots and openings on the appliance front and rear wall should not be obstructed A Evacuation dryer ...

Page 6: ...Level the machine longitudinally and transversally by rotating the adjustable feet thus enabling the leveling by 1 cm Vibrations moving of the appliance and loud operation due to incorrect setting of the adjustable feet shall not be covered by this warranty The appliance should be placed on a surface with concrete base the surface should be dry and clean in order to prevent slipping The adjustable...

Page 7: ... not exceed 800mm The signal light indicates that the container is full and should be emptied preferably after each drying cycle Use the power cord to connect the dryer to the power supply via wall socket Rated voltage and other characteristics are indicated on the name plate located under the door frame of the appliance The wall socket should always be within reach It has to be earthed according ...

Page 8: ...load the drum with items of different sizes Do not load drip wet laundry into the dryer min 800 rpm Pay attention to the labels on the clothes indicating the recommending drying mode see table of textile treatment symbols on the last page Insert the laundry into the drum prior making sure that the drum is empty Close the dryer door Drying procedure Drying procedure A program selection jog B lower ...

Page 9: ...rying delicate laundry After the drying is completed the function returns to initial higher temperature Heater off Turn the heater off by pressing button C if you wish to dry laundry at room temperature LED above button is on Press the START PAUSE button D LED E is on appliance starts to operate after a 2 second pause 10 minutes prior the end of drying program the machine starts the cooling cycle ...

Page 10: ... program is suspended and with the next press of the same button the program is resumed where it had been interrupted Changing the program or the functions If you wish to change the drying time during the drying procedure move button A to the position 0 for about 1 second set new drying time and press the START PAUSE button D The same procedure applies if you wish to change settings selection of f...

Page 11: ... the laundry made of especially sensitive fibers wool silk which may shrink or lose shape It is not necessary to use a fabric conditioner when washing the laundry since drying makes it soft and tender Drying time is much shorter and consequently the energy consumption lower if laundry is well spun prior tumble dring minimum 1000 spin RPM By selecting the most suitable drying program you will avoid...

Page 12: ...ts position and only then close the filter lid If the filter is not regularly cleaned the airflow is obstructed which causes longer drying time and danger of overheating Empty the container and occasionally clean the water condensation device Emptying the water containere Empty the container after every drying procedure pull the container out pull out the draining nozzle pour out the water and rep...

Page 13: ...interior lid Lock the condenser into its place Insert the inner lid to seal well and lock it with a handle Push the exterior lid towards the appliance to lock to its place After five drying cycles you need to do the following remove clean wash and refit the filters on the interior side of the door and the bottom side of door opening remove clean wash and refit water condenser wipe the inside of th...

Page 14: ...he condensation device is clean only with condensation dryer If the room is adequately ventilated If the amount of laundry to be dried is not too big If the evacuation tube is too long only with evacuation dryer max 2 m If the laundry loaded in the drum has not been spun enough or if appropriate drying time has been set If the room is too hot over 25 C applies for condensation dryer The condensati...

Page 15: ...kg 6kg 7kg 6kg 7kg Cotton 6 7 dry for storage 85 98 95 90 110 100 105 140 120 110 130 120 iron dry 75 89 85 80 100 90 95 110 100 90 117 105 Synthetics 3 3 5 1000 rpm 800 rpm dry for storage 35 40 55 50 60 55 45 50 65 60 70 65 iron dry 30 35 45 40 50 45 35 40 50 45 55 50 Delicate 2 5 3 dry for storage z 30 35 50 45 55 50 40 42 60 55 65 60 Ventilation ventilation of dry laundry 20 min possible z com...

Page 16: ...ing in drier not permitted Drain hang on washing line and dry Do not drain hang wet and dry Drain lay on a flat surface and dry Machine drying not permitted Drying at normal temperature Drying at lower temperature Table of textile symbols ...