BOTTOM MOUNT  

REFRIGERATORS AND FREEZERS 

INSTALLATION AND  

OPERATION INSTRUCTIONS

  

 

 

INSPECTION 

When the equipment is received, all items should be carefully checked against the Bill 
of Lading to insure all crates and cartons have been received.  Do not sign the freight 
bill clear until the freight has been properly inspected for damage. All units should be 
inspected for damage including concealed damage by uncrating immediately.  If any 
damage is found, it should be reported to the carrier at once, noted on the Bill of Lading 
and a claim should be filed with the carrier.  This equipment has been inspected and 
tested in the manufacturing facility and has been crated in accordance with 
transportation rules and guidelines.  The manufacture is not responsible for freight loss 
or damages. 
 

INSTALLATION 

The unit has been secured to the shipping base with four bolts.  Remove these bolts 
and separate the unit from the shipping base.  Locate the casters or legs found inside 
the unit.  Attach the casters or legs to the unit base by screwing them into the threaded 
fittings that were used to secure the shipping base.  Use the wrench provided to tighten 
the casters to the unit.  The casters with the brakes should be installed on the front of 
the unit.   For proper drainage of condensate, the unit should be level when placed in its 
permanent location.  Leveling shims are included in the accessories package in the 
cabinet.  Loosen the casters and insert shims between caster and bottom of the unit.  
Retighten the caster.   
 
The exterior of the cabinet and doors have been protected by a plastic covering.  Peel 
this protective covering before installation.  After removing the covering, clean the 
interior and exterior surfaces of the unit with soap and water and a rinse with clean 
water. Do not use chlorinated cleaners on the surfaces as they can cause corrosion.  
 
If the door(s) have come out of alignment during shipping they will need to be adjusted.  
This can be accomplished by opening the door(s) and loosening the screws that hold 
both the top and bottom hinges to the cabinet.  After adjusting the door so it is aligned 
correct, tighten the screws to securely hold the hinges and door(s) in place. The door on 
a single door unit can be reversed in the field by installing Hinge Kit part number 
146524 available from your parts dealer. 
 
The shelves and self clips are packaged inside the unit.  Install the shelf clips on the 
pilasters inside the unit and set the shelves on the clips.  The shelves are adjustable in 
½” increments. 
 

7/10   Rev. A   146527 

1

Summary of Contents for F23-S

Page 1: ...e unit The casters with the brakes should be installed on the front of the unit For proper drainage of condensate the unit should be level when placed in its permanent location Leveling shims are included in the accessories package in the cabinet Loosen the casters and insert shims between caster and bottom of the unit Retighten the caster The exterior of the cabinet and doors have been protected ...

Page 2: ...w 14 F freezer or 50 F refrigerator when the unit is plugged in there will be a three minute delay before the compressor will start The interior light will come on when a door is opened Whenever a door is opened the door open light on the display will be lit and the evaporator fans will stop The fans will start three seconds after the door is closed If a door is open for more than 30 seconds the d...

Page 3: ...condenser coil disconnect the unit from power Periodic cleaning of the condenser coil will aid the heat transfer of the refrigeration system and increase its efficiency Cleaning is recommended a minimum of every 6 months To accomplish this remove the lower front grill from the cabinet The condenser coil is located behind the grill Use a soft bristled brush to remove any dirt particles that are on ...

Page 4: ... button to return to display cabinet temperature Setting Temperature Differential The temperature differential is the amount of swing that the cabinet temperature does either side of the temperature set point If the temperature set point is 36 F and the temperature differential is 8 F the compressor will start when the control shows 40 F and stop when the control shows 32 F The default temperature...

Page 5: ...fy button to return to display cabinet temperature Setting Forced Defrost To start a forced defrost Press Mode Set button Press Up or Down button until dF is displayed Press Manual DF for 2 seconds to start a forced defrost To stop a forced defrost During a forced defrost press Manual DF button for 2 seconds to stop a forced defrost dF will flash five times and then return to normal operation TROU...

Page 6: ...2 Compressor 1 2HP 3 4HP 1 1HP 3 8HP 3 8HP 1 2HP Power Voltage 115V 115V 115 208 230V 115V Plug In Installation NEMA 5 15P NEMA 14 20P NEMA 5 15P Amps 8 5A 9 5A 9 0A 7 5A 7 5A 10 0A Range of Temperature Below 0 F 32 40 F Refrigerant R404a R134a Net Weight lb 295 499 622 288 475 609 Above specifications are subjected to change without prior notice for quality improvement The nameplate includes Seri...