RESIDUAL RISKS
19.
The residual risks associated with the machine are minimized by the manufacturing standards.
Nevertheless, the following situations can occur due to incorrect use of the product:
Spilling of liquids on the floor that can render the treading surface slippery
RESIDUAL RISKS
N°
1
2
3
Risk of electrocution due to erroneous connection of the power cord connected
to the 230 Vac voltage socket
There is a possibility of the ejection of objects due to the introduction of solid
bodies into the disposer.
Residual risks are reduced if the instructions and the guidelines contained in this manual are followed stri-
ctly.
MAINTENANCE
20.
The following is a list of the possible defects that can appear, their causes and the proposed countermeasu-
res for resolving them:
EN
27
Problem
Cause
Solution
The disposer
does not work
No electrical power
The thermal safety device has
been tripped
The start switch is in the off
position
There is no water
Damaged electrical cables
Check for the presence of power
on the household electric panel
Check that the mains plug has been
correctly inserted into the wall socket
Press the start-stop pneumatic
push button
Check the position of the water tap
connected to the water supply system
The replacement of damaged electrical cables
has to be performed by the manufacturer or skil-
led / qualified team in order to avoid dangers
Reset the circuit breaker located on the bot-
tom part of the device
ATTENTION
If the suggested remedy does not solve the fault/defect, contact an authorised technical service centre –
DO NOT ATTEMPT MAKESHIFT MANOEUVRES OR OPERATIONS
Summary of Contents for KITFD050
Page 58: ...AR 57 SMEG SMEG...
Page 59: ...1 2 58 AR KITFD050 KITFD075 KITFD100...
Page 61: ...60 AR...
Page 62: ...6 61 AR...
Page 64: ...8 63 AR 1 2 3 4 5 6 7 8 9...
Page 65: ...9 64 AR 1 2 3 4 6 7 8 9 LOCK Id 0 03 A 220 50 60 1 5...
Page 66: ...10 12 11 65 AR 1 2 3 4 5 6 1 1 5 100 150 8 20...
Page 67: ...13 14 66 AR 1 2 3 4...
Page 68: ...15 16 67 AR PE...
Page 69: ...17 18 68 AR...
Page 70: ...19 20 69 AR 1 2 230 3 start stop...