Grease filters
CLEANING METAL SELF- SUPPORTING GREASE FILTERS
Alarm signal reset
• Switch off the lights and extractor motor.
• Press button V2 for at least 3 seconds, until the
leds start to flash.
Cleaning the filters
• The filters must be cleaned when led S1 flashes
or at least every 2 months of operation, or more
frequently for particularly heavy usage.
• Remove the filters one at a time by pushing them
towards the back of the group and pulling down
at the same time.
• Wash the filters, taking care not to bend them.
Allow them to dry before refitting.
• When refitting the filters, make sure that the
handle is visible on the outside.
Disconnecting the Suction Unit
• Disconnect the hood by switching off the two-
pole switch on the mains power supply line, or
by switching off the main power switch.
• Remove the grease filters from the hood.
• If the hood is of the recirculation type, remove
the odour filters.
• Remove the halogen-lamps support by taking
off the two fixing screws.
• Disconnect the power connector Ca and the
control and lighting connector Cmd on the sides
of the unit.
• Turn the levers Lb locking the suction unit, so
that they disconnect from the pins.
• Pull the suction unit forwards so that it unhooks
from the support pins, and remove it downwards
through the air outlet.
Cmd
Ca