background image

 

19 

disconnection of the mains under conditions relating to over-
current category III, in accordance with installation 
instructions. 

Warning! 

Before re-connecting the hood circuit to the mains 

supply and checking the efficient function, always check that 
the mains cable is correctly assembled. 

 

Mounting 

Expansion wall plugs are provided to secure the hood to most 
types of walls/ceilings. However, a qualified technician must 
verify suitability of the materials in accordance with the type of 
wall/ceiling. The wall/ceiling must be strong enough to take 
the weight of the hood. 

Do not tile, grout or silicone this 

appliance to the wall. Surface mounting only. 
Preliminary information for installation of the hood: 

Disconnect the hood during electrical connection, by turning 
the home mains switch off. 
Remove the fat/s filter/s and the carbon filter frame. 
Do not tile, grout or silicone this appliance to the wall. Surface 
mounting only. Do not fix chimney flue to furniture or fly over 
shelves unless the chimney flue can be easily removed, in 
case maintenance is ever required. 

Assembling the chimney flue support/bracket (3 parts): 

The three parts should be fixed with 4 screws, the support 
extension is adjustable and should correspond to the internal 
width of the telescopic chimney flue.  
A

ssembling the deflector  (only when a deflector 

composed of 3 parts is supplied – the deflector should be 
only for the filter version):  

The three parts should be fixed with 2 screws, the deflector 
extension is adjustable and should correspond to the width of 
the chimney flue support, to which it is then fixed.  
  

 

  

Only for the models illustrated in Fig. 1D/8D - 1E/8E - 
1Q/8Q

 

Remove AND CONSERVE the screws that temporarily fix 
the flue units (for reasons of transport), the hood or the 
flue unit (on the basis of the model possessed) with the 
suction unit. 

The two parts should be disassembled to 

facilitate installation.  Check how the parts are fixed together 
to repeat assemblage at the opportune moment.   
Before fixing the hood to the suction unit check that the metal 
band (steam shield) that holds the lamp and the filter/s / 
greases is well attached to the front.  If necessary adjust the 

position of the band forwards until the end stop.   
 

Attention!

 

The chimney is predisposed for installation of the filter 
Version.  
In certain models where it is required to use the cooker hood 
in the suction version then it is possible to overturn the upper 
section of the chimney  
and insert it inside the lower section of the chimney so that the 
air-exit perforations are not visible.   The chimneys in which 
this operation is possible are recognizable by their bracket 
fixing points 

which are repeated also in the lower side of the 

upper section of the chimney (see installation sequence 20a-
20b).  
 

Attention! 

for all pre-assembled models:  

the mounting operations 

“1, 2, 3”

 should not be taken into 

consideration, for installation begin at operation 

“4”

.  

 

1. 

  Rest the suction unit on a flat surface and thread the 

lower part of the hood onto it (consult the figure 
corresponding to the model in possession - Fig. 1C/8C - 
1D/8D - 1I/8I - 1E/8E - 1F/8F - 1G/8G - 1H/8H - 1R/8R - 
1N-1O-1P)

.

 

2. 

  Make all the electrical connections between the two parts 

(Fig. 9)

3. 

  Permanently fix the cooker hood to the suction group with 

the screws (consult the figure corresponding to the model 
in possession - Fig. 1C/8C - 1D/8D - 1I/8I - 1E/8E - 1F/8F 
- 1G/8G - 1H/8H - 1R/8R - 1N-1O-1P)

.

 

4. 

  Using a pencil, draw a line on the wall, extending up to 

the ceiling, to mark the centre.  This will facilitate 
installation 

(Fig. 10)

5. 

  Rest the drilling template against the wall: the vertical 

centre line printed on the drilling template must 
correspond to the centre line drawn on the wall, and the 
bottom edge of the drilling template must correspond to 
the bottom edge of the hood: bear in mind that, when 
installation is complete, the underside of the hood must 
be at least 50 cm above the cooker top in the case of 
electric cookers, and at least 65 cm above the cooker top 
in the case of gas or mixed cookers. 

6.

  Place the lower support bracket on the perforation 

diagram making it coincide with the traced triangle, mark 
the two external holes and perforate.  Remove the 
perforation diagram, insert two wall-dowels and fix the 
support bracket of the hood with two 5x45 mm screws  

(Fig. 10)

 

Attention: only the models illustrated in Fig. 1Q/10Q:

 

 

Fix the central bracket with two screws and wall-dowels 
above the lower bracket (see perforation diagram for 
positioning the holes).   

7.

  If supplied dismantled, fix the hooks to the side of the 

aspiration group with two screws (fig. 10a). Hang the 
hood onto the lower bracket.  

8. 

  Adjust the distance of the hood from the wall. 

9.

   Adjust the horizontal position of the hood. 

10. 

  Using a pencil mark the cooker hood permanent drill hole 

Summary of Contents for KSMD910X1

Page 1: ...ontaggio e d uso ES Montaje y modo de empleo PT Instruções para montagem e utilização NO Instrukser for montering og bruk FI Asennus ja käyttöohjeet SV Monterings och bruksanvisningar DA Bruger og monteringsvejledning RU Инструкции по монтажу и эксплуатации CS Návod na montáž a používání PL Instrukcja montażu i obsługi SK Návod k montáži a užití TR Montaj ve kullanõm talimatlarõ ...

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ......

Page 9: ......

Page 10: ...s caused to the appliance as the result of the non observance of the instructions included in this manual This appliance is marked according to the European directive 2002 96 EC on Waste Electrical and Electronic Equipment WEEE By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused...

Page 11: ...the filter Version In certain models where it is required to use the cooker hood in the suction version then it is possible to overturn the upper section of the chimney and insert it inside the lower section of the chimney so that the air exit perforations are not visible The chimneys in which this operation is possible are recognizable by their bracket fixing points G which are repeated also in t...

Page 12: ...l to the command plate Attention The terminal pivot on the plate MUST correspond to the drill hole on the connection block situated at the back of the control panel 21 Slide the bottom section of the chimney down until it completely covers the suction unit and slots into the housing provided on top of the hood Fig 18 22 Fix the lower section of the chimney with two screws only for the model in Fig...

Page 13: ...FF key Display off Stand by led lit on the display press for a long time to select the function desired B Lighting on off C Timer for selected speed visualizes the speed selected and flashing LED on the lower side of the display This knob permits the operation of the cooker hood for a established period 20 minutes if the speed selected is 1 15 minutes if the speed selected is 2 10 minutes if the s...

Page 14: ...nd try once more before contacting the Technical Assistance Service Warning Always press the fan off button A before disconnecting the hood from the mains supply Functioning 6 key electronic model 1 2 3 4 5 F 6 1 Motor OFF key 2 Diminishes the speed 3 Increases the speed 4 5 15 minutes timer Inserts and extracts the timer The speed in function is turned off automatically 5 Resets carbon filters sa...

Page 15: ...riate maintenance or failure to observe the above safety recommendations Grease filter Fig 2 This must be cleaned once a month or when the filter saturation indication system if envisaged on the model in possession indicates this necessity using non aggressive detergents either by hand or in the dishwasher which must be set to a low temperature and a short cycle When washed in a dishwasher the gre...

Page 16: ...rry out any replacements Only for the illustrated model in Fig 1L Fig 6L 1 Open the front panel v upwards which holds the lamp in place ensuring to hold the lamp z with one hand 2 Replace the damaged lamp with one of identical technical characteristics Attention To guarantee the equivalent quality of lighting it is recommended to use the same type of lamp bulb Philips neon Lamp bulb 13W Code Ref 8...