background image

SAFETY WARNINGS
RANGE HOODS

• THERE SHALL BE ADEQUATE VENTILATION OF THE ROOM WHEN THE RANGE
HOOD IS USED AT THE SAME TIME AS APPLIANCES BURNING GAS OR OTHER FUELS.
(NOT APPLICABLE TO APPLIANCES THAT ONLY DISCHARGE THE AIR BACK INTO
THE ROOM)
• THERE IS A RISK OF FIRE IF CLEANING IS NOT CARRIED OUT IN ACCORDANCE
WITH THE INSTRUCTIONS.
• DO NOT FLAMBÉ UNDER THE RANGE HOOD.
• CAUTION: ACCESSIBLE PARTS MAY BECOME HOT WHEN USED WITH A COOKING
APPLIANCE.
• THE APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING CHILDREN)
WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES, OR LACK OF
EXPERIENCE AND KNOWLEDGE, UNLESS THEY HAVE BEEN GIVEN SUPERVISED
OR INSTRUCTION CONCERNING USE OF THE APPLIANCE BY A RESPONSIBLE
PERSON FOR THEIR SAFELY.
• YOUNG CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT
PLAY WITH THE APPLIANCE.
• IF THE SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY THE
MANUFACTURER OR ITS SERVICE AGENT OR A SIMILARLY QUALIFIED PERSON IN
ORDER TO AVOID A HAZARD. 

FOR INSTALLATION INSTRUCTIONS:

• THE EXHAUST AIR MUST NOT BE DISCHARGED INTO A FLUE WHICH IS USED FOR
EXHAUSTING FUMES FROM OTHER APPLIANCES BURNING GAS OR OTHER FUELS.
(NOT APPLICABLE FOR APPLIANCES WHICH ONLY DISCHARGE AIR BACK INTO THE
ROOM)
• THE MINIMUM DISTANCE BETWEEN THE SUPPORTING SURFACE FOR THE COOKING
VESSELS ON THE HOB AND THE LOWEST PART OF THE RANGE HOOD:

WHEN THE RANGE HOOD IS LOCATED ABOVE A GAS APPLIANCE, THIS DISTANCE
SHALL BE 65CM. IF THE INSTRUCTIONS FOR INSTALLATION FOR THE GAS HOB
SPECIFY A GREATER DISTANCE, THIS MUST BE TAKEN INTO ACCOUNT. (THE
DISTANCE OF 65CM CAN BE REDUCED FOR NON COMBUSTIBLE PARTS OF RANGE
HOODS AND PARTS OPERATING AT SAFETY EXTRA LOW VOLTAGE PROVIDED
THESE PARTS DO NOT GIVE ACCESS TO LIVE PARTS. DISTANCE MAY BE REDUCED
TO 60CM TO ALIGN WITH THE AGA CODE.

• REGULATIONS CONCERNING THE DISCHARGE OF AIR HAVE TO BE FULFILLED

                                                                                                                                    04308297/1

Summary of Contents for LIFTB900

Page 1: ...OVER A GAS RANGE OR GAS COOKING HOB A DIFFERENT SPECIFIC MINIMUM HEIGHT REQUIREMENT MAY BE REQUIRED BY THE RELEVANT GAS AUTHORITIES IF THE SUPPLY CORD IS DAMAGED IT MUST BE REPLACED BY THE MANUFACTURER OR ITS SERVICE AGENT OR A SIMILARY QUALIFIED PERSON IN ORDER TO AVOID A HAZARD THE APPLIANCE IS NOT INTENDED FOR USE BY YOUNG CHILDREN OR INFIRM PERSONS WITHOUT SUPERVISION YOUNGCHILDRENSHOULDBESUPE...

Page 2: ...HE SUPPLY CORD IS DAMAGED IT MUST BE REPLACED BY THE MANUFACTURER OR ITS SERVICE AGENT OR A SIMILARLY QUALIFIED PERSON IN ORDER TO AVOID A HAZARD FOR INSTALLATION INSTRUCTIONS THE EXHAUST AIR MUST NOT BE DISCHARGED INTO A FLUE WHICH IS USED FOR EXHAUSTING FUMES FROM OTHER APPLIANCES BURNING GAS OR OTHER FUELS NOT APPLICABLE FOR APPLIANCES WHICH ONLY DISCHARGE AIR BACK INTO THE ROOM THE MINIMUM DIS...

Page 3: ...d oil is especially dangerous in this respect Do not use uncovered electric grates To avoid possible risks of fire always comply with the indicated instructions when cleaning anti grease filters and when removing grease deposits from the appliance This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and know...

Page 4: ...areação do local quando uma coifa e aparelhos alimentados com energia diferente daquela elétrica aquecedor a gás a óleo a carvão etc forem usados contemporaneamente Isso porque a coifa aspirante evacuando o ar pode criar umapressãonegativanolocal Apressãonegativado local não deve superar os 0 04mbar evitando assim o redemoinho dos gases de descarga da fonte de calor É necessário portanto equipar o...

Page 5: ...ëëçíéêÜ 43 Română 46 Čeština 49 Slovensky 52 Istruzioni per l uso Instructions for use Betriebsanleitung Mode d emploi Instrucciones de uso Instruções de uso Gebruiksaanwijzingen Ðóêîâîäñòâî ïî ýêñïëóàòàöèè Brugsanvisning Käyttöohjeet Bruksanvisning Ïäçãßåò ñÞóçò Instrucţiuni de utilizare Návod k použití Návod na používanie ...

Page 6: ... Mobile Cabinet cutting Kabinett Schneiden Cabinet de coupe Gabinete de corte Corte Mobile Kabinet snijden Кабинет резки Skab skæring Kaappi leikkaus Skåp skärning Κοπή κινητά Tăiere mobile Rezanie mobilným Rezanje mobilne 279 5 139 5 270 267 358 363 735 740 292 297 ...

Page 7: ...3 1A 3 4 5 3 9 x 9 5 mm 4 2 x 15 mm 2 1B ...

Page 8: ...4 6A 7A 6B 7B 8A 4 2 x 15 mm 7A 4 2 x 15 mm 7B ...

Page 9: ...5 8B ...

Page 10: ...ed on the data plate inside the appliance itself In case your appliance is not furnished with a non separating flexible cable and has no plug or has not got any other device ensuring omnipolar disconnection from the electricity main with a contact opening distance of at least 3 mm such separating device ensuring disconnection from the main must be included in the fixed installation If your unit fe...

Page 11: ... P5 or P6 pressed down 2 the 5 Timer function is activated When the time has run out the motor turns off and the lift closes The LEDs change from High to Low intensity When the function is active the LED corresponding to the current motor speed blinks Filter alarm display Grease filters After 30h of motor operation the LED of the P1 button comes on for 30 every time the motor turns off Charcoal fi...

Page 12: ...cohol WHAT NOT TO DO do not use abrasive or corrosi ve products e g metal sponges brushes too hard brushes very aggressive detergents etc Cleaning the grease filters WHEN TO CLEAN IT clean it at least every 2 months to prevent the risk of fire HOW TO REMOVE THE FILTERS push the catch near the handle towards the rear of the hood and pull the filter downwards HOW TO CLEAN THE FILTERS hand wash or in...