background image

Installation

44

5.4 Gas connection

General information

Connection to the gas mains can be made 
using a rigid copper pipe or a continuous 
wall steel hose in compliance with the 
provisions established by the applicable 
standard. 
For supplying it with other types of gas, see 
chapter “5.5 Adaptation to different types 
of gas”. The gas in
let connection is 
threaded ½” external gas (ISO 228-1).

Connection with a steel hose

Make the connection to the gas mains 
using a continuous wall steel hose whose 
specifications comply with the applicable 
standard.
Carefully screw the connector 

3

 to the gas 

connector 

1

 of the appliance, placing the 

seal 

2

 between them.

Gas leak

Danger of explosion

•  After carrying out any operation, check 

that the tightening torque of gas 
connections is between 10 Nm and 
15 Nm.

•  If required, use a pressure regulator that 

complies with current regulations.

•  At the end of the installation, check for 

any leaks with a soapy solution, never 
with a flame.

•  The hoses should not come into contact 

with moving parts and should not be 
crushed in any way.

Summary of Contents for PVL675LCN

Page 1: ...ce 39 4 1 Instructions 39 4 2 Cleaning the appliance 39 5 Installation 41 5 1 Safety instructions 41 5 2 Section cut from the countertop 41 5 3 Mounting 42 5 4 Gas connection 44 5 5 Adaptation to different types of gas 46 5 6 Electrical connection 53 We advise you to read this manual carefully which contains all the instructions for maintaining the appliance s aesthetic and functional qualities Fo...

Page 2: ... carry out installation and assistance interventions according to the standards in force Do not modify this appliance Do not insert pointed metal objects cutlery or utensils into the slots in the appliance Do not try to repair the appliance yourself or without the intervention of a qualified technician If the power supply cable is damaged contact technical support immediately and they will replace...

Page 3: ...isposed of separately from other waste Directives 2002 95 EC 2002 96 EC 2003 108 EC The appliance does not contain substances in quantities sufficient to be considered hazardous to health and the environment in accordance with current European directives To dispose of the appliance Cut the power supply cable and remove it along with the plug Deliver the appliance to the appropriate recycling centr...

Page 4: ...before using the appliance 1 7 How to read the user manual This user manual uses the following reading conventions 1 Sequence of instructions for use Standalone instruction Instructions General information on this user manual on safety and final disposal Description Description of the appliance and its accessories Use Information on the use of the appliance and its accessories cooking advice Clean...

Page 5: ...Description 33 EN 2 Description 2 1 General Description 60 cm 75 cm ...

Page 6: ...ar left Central Rear right Central right Front right Burner knobs Useful for lighting and adjusting the hob burners Press and turn the knobs anti clockwise to the value to light the relative burners Turn the knobs to the zone between the maximum and minimum setting to adjust the flame Return the knobs to the position to turn off the burners ...

Page 7: ...ot leave the appliance unattended during cooking operations where fats or oils could be released Do not spray any spray products near the appliance Do not touch the appliance s heating elements when it is running Leave them to cool before cleaning Keep children under the age of eight away from the appliance when it is in use Improper use Risk of damage to surfaces Do not use aluminium foil to cove...

Page 8: ...y go out when the knob is released In this case the thermocouple has not heated up sufficiently Wait a few moments and repeat the operation Keep the knob pressed in longer Correct positioning of the flame spreader crowns and burner caps Before lighting the hob burners make sure that the flame spreader crowns are correctly positioned in their housings with their respective burner caps Make sure tha...

Page 9: ...hob For better burner efficiency and to minimise gas consumption use pans with lids and of suitable size for the burner so that the flames do not reach up the sides of the pan Once the contents come to the boil turn down the flame far enough to ensure that the liquid does not boil over To prevent burns or damage to the hob or the counter top during cooking all pans or griddles must be placed insid...

Page 10: ...urner on maximum power for no more than 10 minutes It is recommended you reduce the power during cooking Do not allow the burner flames to extend beyond the edge of the griddle Leave a gap of at least 150 mm between the edge of the griddle and the side wall Do not place the griddle over more than one burner at the same time ...

Page 11: ...n them in lukewarm water and non abrasive detergent Make sure to remove any encrustations Dry them thoroughly and return them to the hob Improper use Risk of damage to surfaces Do not use steam jets to clean the appliance Do not use cleaning products containing chlorine ammonia or bleach on parts made of steel or that have metallic surface finishes e g anodizing nickel or chromium plating If it co...

Page 12: ...dle Flame spreader crowns and burner caps For easier cleaning the flame spreader crowns and the burner caps can be removed Wash them in hot water and non abrasive detergent Carefully remove any encrustation then wait until they are perfectly dry Refit the flame spreader crowns making sure that they are correctly positioned in their housings with their respective burner caps In case of a malfunctio...

Page 13: ...ation Risk of fire Check that the carcase material is heat resistant Check that the carcase has the required openings The minimum clearance between a ventilation hood and the cooking surface must be at least the distance indicated in the ventilation hood installation instructions The following operation requires building and or carpentry work and must therefore be carried out by a competent trades...

Page 14: ...en unit or drawers If there are other pieces of furniture lateral walls drawers etc dishwashers or fridges under the hob a double layer wooden base must be installed at least 20 mm from the bottom of the hob to avoid any accidental contact It must only be possible to remove the double layer base using suitable equipment 150 x 150 mm required for gas connection opens on bottom opens on rear If inst...

Page 15: ... assembly With steel hob To prevent leakage of liquid between the frame of the hob and the work surface put the insulating seal provided in position before assembly 1 Refer to the dimensions in the figure bearing in mind that the long front side must brush against the hole 2 Use light pressure to make the seal stick to the edge around the hole cut in the worktop 3 Carefully trim the surplus edge a...

Page 16: ...nection to the gas mains using a continuous wall steel hose whose specifications comply with the applicable standard Carefully screw the connector 3 to the gas connector 1 of the appliance placing the seal 2 between them Gas leak Danger of explosion After carrying out any operation check that the tightening torque of gas connections is between 10 Nm and 15 Nm If required use a pressure regulator t...

Page 17: ...n force The supply pressure must comply with the values indicated in the table in Gas types and Countries Room ventilation The appliance should be installed in rooms that have a permanent air supply in accordance with the standards in force The room where the appliance is installed must have enough air flow for the regular combustion of gas and the necessary air change in the room itself The air v...

Page 18: ...taller must issue a certificate of conformity 1 Extraction using a hood 2 Extraction without a hood A Single natural draught chimney B Single chimney with extractor fan C Directly outdoors with wall or window mounted extractor fan D Directly outdoors through wall Air Combustion products Extractor fan 5 5 Adaptation to different types of gas If other types of gas are to be used the nozzles must be ...

Page 19: ...he flame spreader crowns and relative burner caps 3 Pull the knobs and the knob bezels upwards to remove them 4 For each burner unscrew the three screws that fix the burner support rings to the hob top Between knob and the knob bezel there is a spring that is not shown in the figure ...

Page 20: ...ll go 2 Use a spanner to remove the nozzles C and install the new ones for the required gas supply following the indications given in the relevant table see Gas types and Countries 3 Adjust the air flow by moving the air regulator B to obtain the distance D given in the corresponding table see Gas types and Countries 4 After adjusting each burner reassemble the appliance correctly The nozzle tight...

Page 21: ...ot go out 5 Repeat the operation on all gas cocks Adjusting the minimum setting for LPG Tighten the screw located at the side of the tap rod clockwise all the way Lubricating the gas cocks Over time the gas taps may become difficult to turn and get blocked Clean them internally and replace the lubrication grease Following adjustment to a gas other than the one originally set in the factory replace...

Page 22: ...as G25 G25 20 mbar 4 LPG G30 31 G30 31 28 37 mbar G30 31 30 37 mbar G30 31 30 30 mbar 5 LPG G30 31 G30 31 50 mbar 6 Town gas G110 G110 8 mbar 7 Town gas G120 G120 8 mbar It is possible to identify the available gas types based on the country the appliance is to be installed in Refer to the heading number to identify the correct values in the Burner and nozzle characteristics tables ...

Page 23: ...city kW 1 0 1 6 2 4 2 9 3 5 Nozzle diameter 1 100 mm 75 94 115 128 138 Reduced flow rate W 400 500 900 900 1100 Primary air mm 10 10 2 2 2 Marking on nozzle F4 X S S S 4 LPG G30 31 30 37 mbar AUX SR RR R UR Rated heating capacity kW 0 9 1 6 2 5 2 9 3 5 Nozzle diameter 1 100 mm 48 62 76 81 90 Reduced flow rate W 400 500 900 900 1100 Primary air mm 10 10 10 10 10 Marking on nozzle Rated flow rate G3...

Page 24: ...zzle diameter 1 100 mm 130 165 215 245 280 Reduced flow rate W 400 500 900 900 1100 Primary air mm OPEN OPEN 4 4 4 Marking on nozzle H2 H3 H1 7 Town gas G120 8 mbar AUX SR RR R UR Rated heating capacity kW 1 0 1 6 2 4 2 9 3 4 Nozzle diameter 1 100 mm 125 160 200 220 260 Reduced flow rate W 400 500 900 900 1100 Primary air mm OPEN OPEN 4 4 4 Marking on nozzle H2 H2 H1 H1 ...

Page 25: ... should be located near the appliance and in an easily reachable position Connection with plug and socket Make sure that the plug and socket are of the same type Avoid using adapters and shunts as these could cause overheating and a risk of burns Power voltage Danger of electrocution Have the electrical connection performed by authorised technical personnel Use personal protective equipment The ap...

Page 26: ......