Instructions for the user
112
Two minutes after the start of the cleaning cycle
(Pyrolysis), a locking device which prevents opening
of the door will be tripped.
will light up to
indicate that the locking device has been activated.
At the end of the cleaning cycle, the locking device
will remain active until the temperature inside the
oven has reached a safety threshold. When the oven
has cooled down, collect the residues from
automatic cleaning with a damp microfibre cloth.
To select a cleaning cycle with delayed start
,
after setting the duration press the temperature
selection knob once.
and the current time will
appear on the display.
(Temperature knob)
Turn the knob right or left to increase or decrease
the time when you want to start the cleaning cycle.
(Temperature knob)
A few seconds after the required duration is set,
and
will stay lit, and the oven will wait for the
starting time set for the cleaning cycle.
It is not possible to select any functions once the door locking device has been
activated. Wait for
to go out.