Instructions for the installer
10
4.1
Connection to LPG
Use a pressure regulator and make the connection to the tank according
to the provisions of standards regulations in force. Make sure that feed
pressure conforms to the levels shown in the table in paragraph “5.2
Regulation for LPG”.
4.2
Room ventilation
The cooktop should only be installed in rooms with permanent
ventilation, as required by the standard regulations in force The room in
which the hob is installed must have sufficient air flow to satisfy the
requirements of normal gas combustion and of necessary air exchange
in the room. The air intakes, protected by screens, must be appropriately
sized (regulations in force) and positioned so that they are not blocked in
any way.
The room where the oven is installed should be suitably ventilated to
avoid overheating or excess humidity produced by cooking. If it will be
used for a lengthy amount of time, a window should be opened or the
speed of any fans should be increased.
4.3
Discharge of combustion products
Discharge of combustion products must be guaranteed by means of
hoods connected to a natural draught flue with certain efficiency, or by
means of forced aspiration.
An efficient aspiration system requires careful planning by a specialist
capable of installing it, respecting the positions and distances prescribed
by the standards. After installation, the installer must issue a certificate of
conformity.