Activated Charcoal Filter (Recirculation Version) 

•  This cannot be washed or regenerated, and must be changed when all the command LEDs 

start to flash, or at least once every 4 months.  

Activating the alarm signal 

•  In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on installation or at 

a later date. 

•  Press and hold the 

Delay 

button (

T4

) on the keypad for 

5 seconds

 and the following will be dis-

played: 

  •  Leds (L1-L2-L3) flash twice – Activated Charcoal Filter saturation alarm ACTIVATED. 
  •  Leds (L1-L2-L3) flash once – Activated Charcoal Filter saturation alarm DEACTI

 VATED. 

CHANGING THE ACTIVATED CHARCOAL FILTER 

Resetting the alarm signal

 

• Press button 

T1 

(see the paragraph on Use). 

Changing the Filter

 

•  Remove the Metal grease filters. 
•  Remove the saturated Activated Charcoal filter, as shown in 

the figure. 

•  Fit the new Filter, hooking it into place. 
•  Replace the Metal grease filters. 

 

 

Lighting 

LIGHT REPLACEMENT 

20 W halogen light. 

•  Remove the snap-on lamp cover by levering it from under the 

metal ring, supporting it with one hand. 

•  Remove the halogen lamp from the lamp holder by pulling 

gently. 

•  Replace the lamp with a new one of the same type, making 

sure that you insert the two pins properly into the housings on 
the lamp holder. 

•  Replace the snap-on lamp cover.

 

 

 

Summary of Contents for SHIG910X

Page 1: ...Instructions Manual SHIG910X ...

Page 2: ...2 2 INDEX RECOMMENDATIONS AND SUGGESTIONS 3 CHARACTERISTICS 4 INSTALLATION 6 USE 10 MAINTENANCE 11 EN ...

Page 3: ...ks WARNING Failuretoinstallthescrewsorfixingdeviceinaccordancewiththeseinstructionsmay resultinelectricalhazards USE Theextractorhoodhasbeendesignedexclusivelyfordomesticusetoeliminatekitchensmells Neverusethehoodforpurposesotherthanforwhichithasbeendesigned Neverleavehighnakedflamesunderthehoodwhenitisinoperation Adjust the flame intensity to direct it onto the bottom of the pan only making sure ...

Page 4: ...EN 4 4 CHARACTERISTICS Dimensions 650mm minimum ...

Page 5: ...ø 150 120 mm 10 1 Dumper 14 1 1 Air Outlet Connector Extension 15 1 Air Outlet Connector 24 1 Connection box 25 Pipe clamps not included 26 2 Cable clamps 27 1 Finishing plug Ref Q ty Installation Components 11 4 Wall Plugs ø 10 12c 6 Screws 2 9 x 6 5 12e 2 Screws 2 9 x 9 5 12f 2 Screws M4 x 80 12g 4 Screws M6 x 80 12h 4 Screws 5 2 x 70 12q 4 Screws 3 5 x 9 5 21 1 Drilling template 22 8 6 4 mm int...

Page 6: ...ings with wall thickness of 20 mm drill ø 10 mm immediately insert the Dowels 11 supplied For wooden beam ceilings drill according to the wood screws used For wooden shelf drill ø 7 mm For the power supply cable feed drill ø 10 mm For the air outlet Ducted Version drill according to the diameter of the external air ex haust duct connection Insert two screws of the following type crossing them and ...

Page 7: ...do not come out of their seats in the slotted holes The frame mountings must be secure to withstand the weight of the hood and any stresses caused by the occasional side thrust applied to the device On completion check that the base is stable even if the frame is sub jected to bending In all cases where the ceiling is not strong enough at the suspension point the installer must provide strengtheni...

Page 8: ...f the extension pieces 14 1 is hori zontally and vertically aligned with the chimney outlets Otherwise remove the lower chimney and adjust the position by inverting the extension pieces for air outlet connection 14 1 or by cutting the hood body extension piece 14 if any along one of the chases destined to the predetermined extension lengths Replace then the elements as earlier described Fit the di...

Page 9: ...med on the galva nized diffuser support as shown in fig 2 Position the finishing plug 27 over the housing in the diffuser support fixing it us ing a screw 12e 2 9 x 9 5 and applying the 2 cable clamp elements 26 as indicated in figs 3 and 4 Connect the Controls Connector fig 5 Connect the Lighting Connector fig 6 Store both the Connectors in the Protective box 24 and close it with 2 Screws 12e 2 9...

Page 10: ...aturation of the activated charcoal filters T2 Turn the suction motor on at speed two On Press and hold for approximately 5 seconds with all the loads turned off Motor and Lights to enable disable the Remote control 2 flashes Remote control Enabled 1 flash Remote control Disabled T3 Turn the suction motor on at speed three On Press and hold the button for 2 seconds to activate intensive speed This...

Page 11: ...or more frequently if use is particularly intensive Resetting the alarm signal Press button T1 see the paragraph on Use Cleaning the Filters Remove the Filters one at a time pushing them towards the back of the unit and at the same time pulling downward Wash the Filters without bending them and leave them to dry completely before replacing Replace taking care to ensure that the handle faces forwar...

Page 12: ...ctivated Charcoal Filter saturation alarm DEACTI VATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Press button T1 see the paragraph on Use Changing the Filter Remove the Metal grease filters Remove the saturated Activated Charcoal filter as shown in the figure Fit the new Filter hooking it into place Replace the Metal grease filters Lighting LIGHT REPLACEMENT 20 W halogen li...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...436006013_ver2 ...

Reviews: