background image

 

 

 

 

 

EN 

6

 

Hood support mounting 

•  Lean the hood support 3 against the wall making sure that 

holes in the hood support correspond to those in the wall. 

•  Block the hood support to the wall using 4 

12a

 (5 x 70) screws 

supplied with the hood. 

•  Before fastening the screws definitively make sure that the 

support is well-levelled. Only after this  operation proceed with 
the definitive tightening of the screws.    

 

3

12a

Air outlet connection in the ducting version  

When installing the hood in ducting version, basing on the in-
staller’s choice, a rigid or a flexible pipe with a ø 150 o 120 mm 
is used in order to connect the hood to the air outlet piping. The 
pipe connection can be made  on the upper part or on the back 
side of the hood. 

To install the dumper 

10

 

AIR OUTLET ON THE BACK SIDE OF THE HOOD 

•  When drilling the air outlet hole in the wall proceed in accor-

dance with the scheme in the paragraph concerning the wall 
drilling. 

•  In case the connection is made with a ø 120 mm pipe insert the 

reduction flange 

9

 on the hood body outlet. 

•  Fix the pipe with an adequate quantity of pipe clamps. This 

material is not supplied together with the hood. 

•  Remove the charcoal filter if present. 

AIR OUTLET ON THE UPPER PART OF THE HOOD 

•  In case the connection of the hood to the air outlet piping is 

made with a ø 150 mm pipe then use a rigid or a flexible pipe. 

•  In case the connection is made with a ø 120 mm pipe insert the 

reduction flange 9 on the hood body outlet. 

•  Fix the air outlet reduction 

8c

 to the air outlet hole of the hood 

support with the screws supplied together with the hood. 

•  Connect the hood to the piping with a rigid or a flexible pipe. 
•  Fix the pipe with an adequate quantity of pipe clamps. This 

material is not supplied together with the hood. 

•  Remove the charcoal filter if present. 

 

ø 120

9

8c

ø 150

10

10

 

Summary of Contents for SHW410X

Page 1: ...Instructions Manual SHW410X ...

Page 2: ...2 2 INDEX RECOMMENDATIONS AND SUGGESTIONS 3 CHARACTERISTICS 4 INSTALLATION 5 USE 9 MAINTENANCE 10 EN ...

Page 3: ...ks WARNING Failuretoinstallthescrewsorfixingdeviceinaccordancewiththeseinstructionsmay resultinelectricalhazards USE Theextractorhoodhasbeendesignedexclusivelyfordomesticusetoeliminatekitchensmells Neverusethehoodforpurposesotherthanforwhichithasbeendesigned Neverleavehighnakedflamesunderthehoodwhenitisinoperation Adjust the flame intensity to direct it onto the bottom of the pan only making sure ...

Page 4: ...ipped with the Exhaust Group 7 1 tube in PVC 8 1 Directioned grid 8c 1 Air outlet reduction ø 120mm 9 1 Reduction flange ø 150 120 mm 10 1 Dumper Ref Q ty Installation components 11 4 Small blocks ø 10 12a 4 Screws 5 x 70 12b 4 Screws M4 x 15 12e 2 Screws 2 9 x 9 5 13 4 Screws plug M4 Q ty Documentations 1 Instruction booklet 650mm minimum ...

Page 5: ...l line at a minimum of 1050 mm above the Cooker Top As indicated mark a reference point at 100 mm to the right of the vertical reference line Repeat this operation on the other side checking that the two marks are level As indicated mark a reference point at 390 mm above the horizontal reference line and at 100 mm to the right of the vertical reference line Repeat this operation on the other side ...

Page 6: ...g the air outlet hole in the wall proceed in accor dance with the scheme in the paragraph concerning the wall drilling In case the connection is made with a ø 120 mm pipe insert the reduction flange 9 on the hood body outlet Fix the pipe with an adequate quantity of pipe clamps This material is not supplied together with the hood Remove the charcoal filter if present AIR OUTLET ON THE UPPER PART O...

Page 7: ... it laterally with the 4 12b screws Cover the screw seats with the plugs 13 supplied with the hood Recycling version Remove the pre cut piece Lean the hood body on the support and fix it laterally with the 4 12b screws Cover the screw seats with the plugs 13 supplied with the hood Place the directioned grid 8 on the pipe and make sure that it is correctly installed Fix the directioned grid 8 with ...

Page 8: ... them towards the back of the group and pulling down at the same time Being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan Connect the control connector Cmd Connect the Spotlights connector Lux to the socket provided behind the lighting unit cover Replace the filters make sure that the handle is visible on the outside and the lighting...

Page 9: ...aturation of the activated charcoal filters T2 Turn the suction motor on at speed two On Press and hold for approximately 5 seconds with all the loads turned off Motor and Lights to enable disable the Remote control 2 flashes Remote control Enabled 1 flash Remote control Disabled T3 Turn the suction motor on at speed three On Press and hold the button for 2 seconds to activate intensive speed This...

Page 10: ...larly intensive Resetting the alarm signal Press button T1 see the paragraph on Use Cleaning the Filters Open the lighting unit by pulling on the nocth Remove the Filters one at a time pushing them towards the back of the unit and at the same time pulling downward Wash the Filters without bending them and leave them to dry completely before replacing Replace taking care to ensure that the handle f...

Page 11: ...rm ACTIVATED Leds L1 L2 L3 flash once Activated Charcoal Filter saturation alarm DEACTI VATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Press button T1 see the paragraph on Use Changing the Filter Open the lighting unit by pulling on the nocth Remove the Metal grease filters Remove the saturated Activated Charcoal filter as shown in the figure Fit the new Filter hooking it ...

Page 12: ...436006018_ver2 ...

Reviews: