Instructions for the installer
25
3. ADAPTING TO DIFFERENT TYPES OF GAS
Before any intervention, disconnect the power supply of the device.
The cooking hob is inspection-tested for use with G20 (2H) natural gas
at a pressure of 20 mbars. If used with other types of gas, you have to
replace the nozzles and regulate the primary air to the burners. Then
regulate the minimum flame on the gas taps. For nozzle replacement and
burner adjustment you must raise the cooking hob as described in the
following paragraph.
3.1 Removing the top
1.
Slide out the grids, and remove all burner caps, flame cap crowns
and burners.
2.
Remove the screws and nuts A which hold burner supports in place.
3.
Remove plates B.
4.
Lift up top C with the aid of a screwdriver and remove it from its seat.
5.
Replace the burner nozzles according to the specifications in the
reference gas table.
6.
Adjust primary air as described in paragraph “3.2 Regulation for
LPG”.