8. TROUBLESHOOTING
Fault
Cause
Solution
Light on, but motor
does not work
The leaf blocked
Get rid of the blocking
The capacitor damaged
Replace capacitor
The motor jammed bearing
damaged
Replace motor
The internal with of motor off or a
bad smell from the motor
Replace motor
Light does not work,
motor does not work
Beside the above mentioned, check the following:
Light damaged
Replace lights
Power cord looses
Connect the wires as per
the electric diagram
Oil leakage
One way valve and the air
ventilation entrance are not
tightly sealed
Take down the one way
valve and seal with glue
Leakage from the connection of
U-shaped section and cover
Take U-shaped section
down and seal with soap or
paint
Shake of the body
The leaf damaged and causes
shaking
Replace the leaf
The motor is not tightly hanged Lock the motor tightly
The body is not tightly hanged Fixed the body tightly
Insufficient suction
The distance between the body
and the gas top too long
Readjust the distance
Too much ventilation from open
doors or windows
Choose a new place and
resemble the machine
The machine inclines
The fixing screw not tight
enough
Tighten the hanging screw
and make it horizontal
The hanging screw not tight
enough
Tighten the hanging screw
and make it horizontal