EN
2
21
Activated Charcoal Filter (Recirculation Version)
Can be washed in the dishwasher. It must be washed when button
B
flashes or at least once
every 4 months, or more frequently if use is particularly intense. Guaranteed to operate after
washing for up to a maximum of 5 times before requiring replacement. The Alarm signal, if it
has been activated, only appears when the Suction motor is turned on.
Activating the alarm signal
• In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on
installation or at a later date.
• Turn the Lights and the Suction Motor off.
• Press and hold button
F
for 2 seconds:
• LED
B
flashes twice – Activated Charcoal Filter saturation alarm ACTIVATED.
• LED
B
flashes once – Activated Charcoal Filter saturation alarm DEACTIVATED.
CHANGING THE ACTIVATED CHARCOAL FILTER
Resetting the alarm signal
• Turn the Lights and the Suction Motor off.
• Press and hold button
B
for 2 seconds.
Changing the Filter
• Remove the comfort panel.
• Remove the Metal grease filters.
• Remove the metal filter stops from the grease filter and
clean the saturated activated charcoal odour filter.
• Replace the clean activated charcoal odour filter, hooking it
back up to the grease filter using the metal filter stops.
• Replace the Metal grease filters.
• Close the comfort panel.
Lighting unit
Warning
: This appliance is fitted with a white LED lamp classed
as 1M according to EN 60825-1: 1994 + A1:2002 + A2:2001
standards; maximum optical power emitted @439nm: 7µW. Do
not look directly at the light through optical devices (binoculars,
magnifying glasses…).
• For replacement contact technical support. ("To purchase
contact technical support")