3.4
DRAIN CAPILLARY REPLACEMENT
The machine is supplied with the standard drain capillary installed; the softened water
capillary and the hard water capillary are packed in the accessories bag:
-
black (standard capillary for water < 700 µS and < 22°dH)
-
blue (softened water < 700 µS and < 6 °dH)
-
white (hard water < 1200 µS and < 35°dH)
The drain capillary must be selected considering water hardness and conductivity (see
matrix below).
Hardness (°dH)
35
White 30±5%
22
Black 40±5%
White 30±5%
6
Blue 55±5%
Black 40±5%
100
700
1200
Conductivity µS
The machine must not be installed with inlet water > 1200 µS or > 35 °dH.
Using a small screwdriver, remove the fixing o-ring from the 4mm fittings.
Push the fitting collet and remove the black capillary.
Put the o-rings on the 4mm pipe and push the tube inside the fittings.
Using a small screwdriver, put the fixing o-ring below the fitting collets.
Item:
1. Capillary pipe 4mm
2. Fitting 6-4mm
3. Fixing o-ring
1
2
1
3
1
2
3