81
Accessories
10-378 FOAM MARKER PARTS LIST
REF# PART#
DESCRIPTION
QUANTITY
REF#
PART#
DESCRIPTION
QUANTITY
2
16-987
Foam Nozzle Mounting Kit
1 per boom
3
15-507
Foamer Tubing
2
4
Clear Tubing
5
15-511
Foam Nozzle
2
6
Blue Tubing
7
15-510-01
Nozzle Mounting Rod
2
8
Boom
9
16-795
Square Clamp
4
INSTALLATION INSTRUCTIONS
1. Slide hose clamp onto drop tube of foam nozzle.
2. Place splined end of Nozzle mounting rod (Ref 7) into top of foam nozzle (Ref 5). Tighten screw.
3. Slide two foam nozzle mounts (Ref 2) onto the rod. Place square clamps (Ref 9) on foam nozzle mounts and mount
the square clamps to the boom (Ref 8). Adjust foam nozzle mounts and clamps so nozzle assembly will clear end
of boom. Tighten foam nozzle mounts and square clamps to prevent side to side movement. Do the same to the
other side.
4. Being careful not to cut the tubing (Ref 3), cut the over sleeve back approximately 2" (5 cm) to expose blue (Ref 6)
and clear tubing (Ref 4).
5. Remove blue wing nut from top connector of foam nozzle and slide it on the blue tube with the threads facing
toward end of tube. Slide blue tube all the way over the top of the small tube on foam nozzle. Slide wing nut back to
the threads and hand tighten. Follow the same steps for the clear tube and tube nut.
6. Route the tubing along underside of main frame using tie downs as necessary.
7. Install opposite ends of air-liquid tubes to compressor, again cutting back the over sleeve approximately 2" (5 cm)
and inserting blue and clear tubes for the left boom section into the tubing connectors (Ref A) on the right side of
compressor as far as possible.
8. Follow the same steps for the right boom tubing. Notice the right boom is inserted into left side of compressor. To
release tubing from compressor, hold black ring around tubing, and pull tube out.
9. Hose's must be routed on bottom of the boom square tubing.
10. Mark 6 inches in from inside edge of foamer nozzle mounting bracket on square boom tubing.
11. Connect small plastic electrical plug under compressor to electrical extension cable.
12. For
Spray Star 1600
route extension cable under engine along the mainframe cross bar, using tie downs as neces
-
sary.
13. Cut cable and strip casing, allowing enough length to connect to fuse block.
14. Strip and connect slide on connectors to each wire and use the heat shrink.
15. Connect black negative (-) wire to the ground and connect red wire to the positive (+).
16. Insert 10 amp fuse into slot which red wire was attached to.
Summary of Contents for 10-100-D
Page 13: ...11 NOTES ...
Page 14: ...12 Diagrams WIRING DIAGRAM ...
Page 16: ...14 Diagrams HYDRAULIC DIAGRAM ...
Page 18: ...16 Parts BODY FRAME DRAWING ...
Page 20: ...18 Parts NOSE CONE DRAWING ...
Page 22: ...20 Parts FRONT AXLE DRAWING ...
Page 24: ...22 Parts SEAT CONSOLE AND ROPS DRAWING ...
Page 26: ...24 Parts FUEL TANK DRAWING ...
Page 28: ...26 Parts OIL TANK OIL FILTER OIL COOLER DRAWING ...
Page 30: ...28 Parts FOOT PEDAL LINKAGE DRAWING ...
Page 32: ...30 Parts PUMP DRAWING ...
Page 34: ...32 Parts ENGINE DRAWING ...
Page 36: ...34 Parts PARK BRAKE DRAWING ...
Page 38: ...36 Parts REAR AXLE DRAWING ...
Page 40: ...38 Parts TANK DRAWING TURBO QUAD AGITATOR DRAWING ...
Page 42: ...40 Parts 10 576 ORBITROL DRAWING ...
Page 56: ...54 Accessories 17 835 BOOM DRAWING ...
Page 70: ...68 Accessories 16 906 ELECTRIC HOSE REEL DRAWING ...
Page 72: ...70 Accessories 16 129 MANUAL HOSE REEL DRAWING ...
Page 78: ...76 Accessories 10 378 FOAM MARKER FOR 1000 DRAWING WIRING DRAWING ...
Page 80: ...78 Accessories 10 378 FOAM MARKER DRAWING ...
Page 82: ...80 Accessories FOAMER NOZZLE MOUNT HOSE GUARD MOUNT DRAWING ...
Page 84: ...82 Accessories 14 291 FOAMER REPLACEMENT PARTS ...
Page 90: ...88 Accessories 15 620 CHEMICAL CLEAN LOAD DRAWING ...