15
Operation
Weight of
Solution Per Gallon
Liquid
Density
7.0 lbs.
0.84
8.0 lbs.
0.96
8.34 lbs. - Water
1.00
10.0 lbs.
1.20
10.65 lbs. - 28% N
1.28
10.85 lbs. - 30% N
1.30
11.0 lbs.
1.32
12.0 lbs.
1.44
14.0 lbs.
1.68
SYSTEM SETUP MODE
The System Setup Mode contains the programming steps that customize the monitor to the sprayer or sprayer
components. These include calibration steps and parameters that, once programmed, will likely never change.
To enter the System Setup Mode:
1. First, be sure that the console is ON (if not put it on by pressing the
key and wait until the normal
display is visible).
2. Ensure the Master boom switch is OFF.
3. Then press and hold the
key for 3 seconds to enter the System Setup Mode.
DENSITY
Default = 1.00
If a substance other than water is being sprayed or used as a carrier
(e.g. liquid fertilizer), enter the density of that fluid.
If the solution that you are using can not be found in the chart at
left, the Liquid Density can be calculated as follows:
Density = Weight of Solution
Weight of Water
Use the
or
keys to adjust this value. Once the correct units have been selected, depress the
key
to advance to the next step.