16
Operation
SPEED SENSOR CALIBRATION
Default = 250 pulses/ 300 ft
The speed sensor needs to calibrated in order to provide the proper speed reading. The value for this step is the
number of pulses generated by the speed sensor in 300 feet.
AUTO CALIBRATION
The speed sensor can be automatically calibrated by driving 300 feet. The
console will automatically detect a RADAR sensor (if used).
To start the auto calibration procedure, press simultaneously on the
and
keys. The display now will show CAL.
Now you have to drive to the starting point of the 300 ft distance. Push
the
key to start counting speed pulses as you cross the start point.
Drive 300 ft and press
again to stop the pulse counting as you cross
the finish point.
During the pulse counting the Man LED will be flashing.
The number now on the display is the number of pulses corresponding to
300 ft
The auto calibration procedure can be escaped with the
key. The
console will then return to the previous calibration value.
The calibration number for the 1006 is 965.
The auto speed calibration should be repeated at
least twice and an average of the calibration numbers should be entered.
MANUAL CALCULATION
To manually calculate the proper value for Wheel Speed Sensor pulses, you need to know the circumference of
the wheel to which the sensor is mounted. It can be measured by marking the tire and measuring the distance
covered as that mark makes one full revolution. Then use the following formula:
3,600 x # Magnets on Wheel
Wheel Circumference in Inches
Use the
or
keys to adjust the value. Press the
key to validate the value and advance to the next
programming step.
The wheel calibration should be repeated if you are changing to another wheel diameter.