17
Operation
SPEED CALIBRATION
(CONTINUED)
SIMULATED SPEED
If you enter 0 in this programming step, then the console always works with a simulated speed. This simulated
speed can be used to test out the sprayer at stand still.
The simulated speed feature allows you to check out the sprayer at a certain speed without actually moving the
sprayer. This can be done prior to any spraying activity. The simulated speed value can be changed with the
and
keys when the speed is shown on the display in normal working mode.
TIP SPACING
Default - 20 inches
Use the
or
keys to adjust this value. Once the correct units
have been selected, depress the
key to advance to the next step.
The value shown is represented in inches.
PRESSURE REGULATING MODE
Default = byP
The default value "byP" indicates that the pressure regulating valve is
plumbed in a bypass line. If the default value is correct, press the
key. Use the
or
keys to change the value to throttle (tHr) mode
if needed.
This setting must match the actual plumbed mode of
the regulating valve. Changing this setting will only
reverse the polarity to the valve, it will not effect the physical operation of the valve.
Press the
key to save this parameter and to return to the normal working mode.
APPLICATION UNITS
Default = US
Select the application units to be used for regulation. If you will be using
US units (GPA) press the
key to advance to the next step. If you will
be using trf units (G/1000 ft
2
) use the
or
keys to select this
value.
Once the correct units have been selected, press the
key to advance
to the next step.
Auto
Man
GPA
GPA
GPA