How to deactivate/activate the InLine interface*/the external control*
How to deactivate/activate the InLine interface*/the external con-
trol*
Older X-ray inspection units integrated into a
baggage handling line
or equipped with
safety switches*
at the
conveyor ends
and/or
tunnel entrances and exits
(conveyor end or oversize detectors* - option
InLine vari-
ant Start/Stop
) provide the additional menu item
InLine - control and interface
or
External control
. In this
menu you can deactivate the exchange of signals between the X-ray unit and the baggage handling line or the
safety switches.
The external control being deactivated, the X-ray unit will behave like a standard unit, i.e. the conveyor can be
switched on independently from the running of feed or discharge conveyors, safety switches are without
function. If, e.g., the
X-ACT system
* is to be calibrated on older units, you have to deactivate the interface/the
external control first. On newer units a calibration without deactivating the external control is possible.
A
Warning!
For the feed or discharge conveyors and the conveyor of the X-ray unit can run
in opposite directions
when the external control is deactivated, this can lead to a
high risk of crushing
between the convey-
or belts! See to it that nobody comes near the conveyors and
reactivate
the external control
as soon
as possible
!
In case of deactivated conveyor end or oversize detectors baggage or freight items can
fall off the
conveyors
or
get stuck
at the
tunnel entrances or exits
!
1790
Go to the menu item
InLine - control and
interface*/External control*
in the
Main menu
and
activate this menu item. The menu illustrated beside
is displayed.
To deactivate the interface/the external control, select the setting
Interface inactive/Ext. control inactive
under the item
Interface variant
.
Quit the menu with
r
.
Having left all menus you have to restart the unit. The mes-
sage beside will be displayed. Acknowledge it with
r
.
After the restart the interface/the external control is inactive.
If the interface/the external control is to be reactivated,
e.g. after calibration, carry out the steps mentioned
above and select the setting
Start/Stop
(
Ext. start/stop
signals active
) under Variant.
95587413 01/01/09 © Smiths Heimann
S
Attention!
The X-ray unit is designed for the vari-
ant
Start/Stop
(
Ext. start/stop signals
active
) only! If you choose the wrong
variant, this will lead to
malfunctions
!
1800
2-87
Summary of Contents for HI-SCAN 100100T
Page 2: ...95584681 01 01 09 Smiths Heimann ...
Page 4: ...Contents IV 95584681 01 01 09 Smiths Heimann ...
Page 5: ...95584770 01 03 2003 Smiths Heimann 1 ...
Page 6: ......
Page 10: ......
Page 117: ...95584770 01 03 2003 Smiths Heimann 2 ...
Page 118: ......
Page 122: ......