How to start and terminate your work
How to regenerate the X-ray generators*
(applies only to X-ray units with 300kV X-ray generators*)
If the X-ray unit is equipped with 300kV X-ray
generators*, the generators have to be regener-
ated provided that
more than 72 hours
have
passed after the last operation. After that period
the window illustrated appears when switching
on the X-ray unit.
If any freight items are still placed on the conveyors, do
not
start the regeneration, but abort the process
with
s
.
To convey the freight items back, move the conveyors in
reverse
direction with
m
or
n
.
S
Attention!
Units with newer software* may be set in a way that the keys
n
and
m
either have to be
pressed briefly or have to be kept depressed (according to the arrow symbols in the screen indica-
tion field (
F
1-25))! In the latter case the unit can also be set so as to stop the conveyors only after
up to 3 seconds
after the key is released! An immediate conveyor stop is possible with
1
!
770
If you are going to unload a freight item, stop the conveyors with
1
.
When you have unloaded
all
freight items in the manner described, press shortly the key
m
or
n
pointing
into
the scanning direction
. With that the conveyors are not started, but the window illustrated
above displayed again.
Confirm with
r
. The conveyors are started and the
X-ray generators are automatically regenerated with
re-
duced
high tension. During the process of 18 minutes
the window illustrated is displayed.
95587412 01/01/09 © Smiths Heimann
1-39
I
After longer break times it may happen that the regeneration must be prolonged because of tech-
nical reasons. In this case the
Remaining time
will be automatically reset to 18 minutes.